Coffeemaker User Manual

10
Programming
Batch Settings
Display
Turn the brewer off by pressing the main power switch.
Press the main power switch again to turn the unit on.
52
The last 2 digits of the model number will display briefly, then S t b. S t b
Quickly hold the STOP button for 3 seconds. P r G
The display will show the software version. Example:
0.0 4.8
Press STOP to continue.
Batches are numbered 1 – 3 (CBS-2051e) or 1 – 6 (CBS-2052e / 2052e20)
Next, the first batch parameter is displayed – batch 1, brew volume
1.1 1.50
Use the SCROLL UP and SCROLL DOWN buttons to adjust.
Press the STOP button to go to the next parameter – brew time. 1.2 4.00
Continue this way until all parameters are programmed for batch #1.
(See the chart below for an explanation of each parameter.)
Next, batch #2 programming begins.
2.0 OFF
Batches 2, 3, 5, and 6 may be disabled by leaving them set to “OFF”.
Change to “ON” to enable. Batches 1 and 4 cannot be disabled.
After all batches are programmed, go to temperature settings.
7 200
(See next page)
Important! After programming, you must press the HOT WATER button to save the settings and exit
programming mode, or changes will be lost. You may exit programming at any time.
Batch Parameters
X=Batch Number (1 - 6)
Parameter Name Range Increment Default Setting Comment
X.0 Batch Enabled or
Disabled
On/Off Batch 1 & 4 = ON
Batch 2, 3, 5, 6 = OFF
Batch 1 & 4 cannot
be disabled.
X.1 Brew Volume
(Gallons)
0.25 – 3.00 0.01 1.5 gal. (2051e/2052e)
2.0 gal. (2052e20)
To display liters, see
# 59 in Advanced
Settings section.
X.2 Brew Time (Min:Sec) 2:00 – 24:00 0:30 4:00 minutes
X.3 Bypass Percent 0.00 – 40.0% 1% 0 % Percentage of total
brew volume
X.4 Prewet Percent 0.00 – 15.0% 1% 0 % Percentage of total
brew volume
X.5 Prewet Delay
(Min:Sec)
0:10 – 5:00 0:10 1:00 minute The time between
prewetting and start
of brew cycle.
X.6 Drip Delay (Min:Sec) 0:30 – 6:00
Minutes
0:10 1:30 minute The time between
end of brew cycle
and unlocking of
brew basket.
1.1 1.50
PARAMETER
SETTING
BATCH #
Example:
Left Side
Lar
g
e Batch
Volume 1.5 Gal.