Coffeemaker User Manual

12
Address Description Range Default Comment
60
and
61
Left Brew Valve
Flow Rate
Right Brew Valve
Flow Rate
0.09 – 1.49
If #59 is GAL
or
0.33 – 5.63
If #59 is LTR
0.92
3.48
62
and
63
Left Bypass Valve
Flow Rate
Right Bypass
Valve Flow Rate
0.28 – 0.38
If #59 is GAL
or
1.05 – 1.44
If #59 is LTR
0.33
1.24
Use this to compensate for minor discrepancies in
actual volume versus programmed volume. Set
lower to increase volume, higher to decrease
volume. The following formula can be used to
determine the correct setting:
ACTUAL VOLUME
PROGRAMMED VOLUME
X
CURRENT
SETTING
=
NEW
SETTING
64 Keypad Test 0 - 1 0 Tests function of control panel switches.
0 - Skip keypad test
1 - Keypad test active
Starting at the stop buttons, press each button
that is lit. The display will show the name of the
switch being pressed. Brew switches are named
S1, S2, S3, etc. The hot water switch must be
pressed last, as this will exit the test.
65 Relay Test 0 - 1 0 0 - Skip relay test. Loop back to #50
1 – Relay test active.
Press STOP to continue
Press to save the settings and exit Diagnostic mode.
Press again to exit Programming mode and return to Operating mode.
Relay Test
Tests the individual relays which control various components.
Use either batch button to actuate the relays.
To begin, you must first press the blinking Control Panel Power Switch.
Address Description Comment
90 Left or Single Brew Valve
91 Right Brew Valve
92 Left or Single Bypass Valve
93 Right Bypass Valve
94 Hot Water Faucet
95 Fill Valve
96 Heater To protect the heaters, this test will work only if the tank is full.
97 Left or Single Brew Basket Lock
98 Right Brew Basket Lock
Press to exit Relay Test.
Press again to exit Diagnostic mode.
Press again to exit Programming mode and return to Operating mode.
Warning: During these
tests, hot water may
be dispensed from
t he va lve being tested.