Coffeemaker User Manual

3
Electrical Configuration and Brewing Efficiency
US & Canada
CBS-2051e
1.5 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 11)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E51016 2 X 3 KW 120/208 4.6 22.1 7.7 11.0
120/220 single 3 + ground 5.1 23.4 8.6 11.0
120/240 6.1 25.5 10.3 11.0
CBS-2052e 1.5 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 22)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E52016 Option 1 120/208 4.6 22.4 7.7 18.6
Universal 2 X 3 KW 120/220 single 3 + ground 5.1 23.7 8.6 20.8
Wiring
(Factory Setting)
120/240 6.1 25.8 10.3 22.0
Total 3 X 3 KW
Option 2 120/208 6.9 19.5 11.5 22.0
Heaters 3 X 3 KW 120/220 three 4 + ground 7.7 20.6 12.9 22.0
120/240 9.1 22.5 15.4 22.0
E52026 Option 1 120/208 7.6 36.9 12.8 22.0
Universal 2 X 5 KW 120/220 single 3 + ground 8.5 39.0 14.4 22.0
Wiring
120/240 10.1 42.5 17.1 22.0
Total 3 X 5 KW
Option 2 120/208 11.4 32.0 19.2 22.0
Heaters 3 X 5 KW 120/220 three 4 + ground 12.7 33.9 22.0 22.0
(Factory Setting)
120/240 15.1 36.9 22.0 22.0
CBS-2052e20 2.0 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 18)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E53016 Option 1 120/208 4.6 22.4 5.8 14.0
Universal 2 X 3 KW 120/220 single 3 + ground 5.1 23.7 6.5 15.6
Wiring
(Factory Setting)
120/240 6.1 25.8 7.7 18.0
Total 3 X 3 KW
Option 2 120/208 6.9 19.5 8.6 18.0
Heaters 3 X 3 KW 120/220 three 4 + ground 7.7 20.6 10.1 18.0
120/240 9.1 22.5 11.6 18.0
E53026 Option 1 120/208 7.6 36.9 9.6 18.0
Universal 2 X 5 KW 120/220 single 3 + ground 8.5 39.0 11.2 18.0
Wiring
120/240 10.1 42.5 12.8 18.0
Total 3 X 5 KW
Option 2 120/208 11.4 32.0 14.4 18.0
Heaters 3 X 5 KW 120/220 three 4 + ground 12.7 33.9 16.5 18.0
(Factory Setting)
120/240 15.1 36.9
16.5 18.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.
Export
CBS-2051e
1.5 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 11)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E51026 2 X 3 KW 220 single 2 + ground 5.1 23.4 8.9 11.0
CBS-2052e 1.5 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 22)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E52036 2 X 3 KW 220 single 2 + ground 5.1 23.7 8.6 20.8
CBS-2052e20 2.0 gallons per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 18)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E53036 2 X 3 KW 220 single 2 + ground 5.1 23.7 6.5 15.6
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.