User’s Guide www.fetco.com Models: CBS-2031e / CBS-2031s CBS-2032e / CBS-2032s f f NOTICE TO INSTALLER: Please leave this book with the machine. Table of Contents Contact Information ..................................................2 Description & Features .............................................2 Specifications............................................................2 Requirements........................................................2 Weights and Capacities .................................
Contact Information FETCO® Food Equipment Technologies Company 600 Rose Road Lake Zurich • IL • 60047-0429 • USA Phone: (800) 338-2699 (US & Canada) (847) 719-3000 Fax: (847) 719-3001 Email: sales@fetco.com techsupport@fetco.com Internet: www.fetco.
Electrical Configuration and Brewing Efficiency US & Canada CBS-2031e / CBS-2031s Electrical Config. Code E31045 Can be connected Voltage (AC) Phase Wires KW Maximum Amp draw 1 X 1.5 KW 2 X 1.5 KW 120 120/208 120/220 120/240 single single 2 + ground 3 + ground 1.6 2.4 2.6 3.1 13.0 11.3 12.0 13.0 4.9 7.3 8.2 9.7 11.0 11.0 11.0 11.0 1 X 1.7 KW 2 X 1.7 KW 120 120/208 120/220 120/240 single single 2 + ground 3 + ground 1.8 2.7 3.0 3.5 14.7 12.8 13.5 14.7 5.5 8.3 9.2 11.0 11.0 11.0 11.0 11.
Dimensions & Utility Connections CBS-2031e / CBS-2031s DWG 201108-000 CBS-2032e / CBS-2032s DWG 201109-000 4
Installation (For Qualified Service Technicians Only) Keys To A Successful Installation If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result. Damages resulting from improper installation are not covered by the warranty. Here are the key points to consider before installation: Electrical: All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral may cause damage to the electronic components.
Electrical Connection – US & Canada 1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the brewer’s serial number label. Make sure the electrical service includes neutral. 2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters during the installation process. The heaters are disabled by the control board until the tank is full of water.
Final Setup 1. Turn on the incoming water supply line and inspect both inside and outside of the brewer for leaks in all fittings and tubes 2. Turn on the incoming power. 3. Press the brewer’s main power switch, which is hidden behind the front leg of the brewer. The control panel on/off switch will begin flashing. Press this switch. 4. Within 6 seconds, the hot water tank will begin filling until the water is sensed by the probe at the top of the tank. The display will read “FIL”.
Operating Instructions Control Panel Functions Only switches that are active are illuminated. Switches that are inactive or disabled are invisible. X Main Power Switch Controls all power to brewer Indicator lamp at top of panel. Y Control Panel On/Off Switch Affects only control panel. Does not disconnect main power. Flashing = Off Lit = On Invisible = Main Power Off Z Display ”FILL” = Water tank is filling. ”LO XXX” = Unit is heating, not ready to brew. (XXX = actual temperature.
Programming Display Batch Settings Turn the brewer off by pressing the main power switch. Press the main power switch again to turn the unit on. The last 2 digits of the model number will display briefly, then S t b. Quickly hold the STOP button for 3 seconds. The display will show the software version. Example: Press STOP to continue. Batches are numbered 1 – 2 (single brewers) or 1 – 4 (dual brewers) 32 Stb PrG 0.0 3.2 MAIN POWER SWITCH IS BEHIND FRONT LEG.
Temperature Settings Parameter Name Range 7 Water Temp. (°F) 180°F - 208°F 8 Hot Water Service A (auto) / On / Off 9 Brew at Set Temperature 0-1 Name Range Enter Advanced Settings & Diagnostics 0-1 Parameter 10 Default Setting 200°F A (auto) 1 Default Setting 0 Comment Inside tank. Will be slightly lower at spray head. To display in ° Celsius, see # 58 in Advanced Settings. A= Faucet will dispense only when not brewing. On=Faucet always enabled. Off=Faucet always disabled.
Address 60 and 61 Description Left Brew Valve Flow Rate Right Brew Valve Flow Rate Range 0.35 – 2.24 Default Comment 1.48 Use this to compensate for minor discrepancies in actual volume versus programmed volume. Set lower to increase volume, higher to decrease volume. The following formula can be used to determine the correct setting: If #59 is LTR or 0.09 – 0.59 If #59 is GAL 0.
Error Codes Code Description Possible Cause Corrective Action 001 Internal Error System had to reload default settings. Control board failure. 050 Shorted temperature probe. Probe failure. Clear error. Re-program the brewer to the desired specifications. If error occurs again, replace control board. Replace probe. 051 Open temperature probe. 075 or NO BAS CBS-2031e / 2032e Brew Basket Sensor Bad probe connection, or probe failure. These models do not have brew basket sensors or locks.
Parts Figure 1 – CBS-2031e / CBS-2031s Main Assembly DWG 101194-C ITEM # 1 2 2 3 4 5 5 QTY 1 1 1 2 4 1 1 6 7 7 4 1 1 8 9 10 11 12 13 1 1 1 4 1 1 PART # 001051 108001 108037 29007 15007 51042 51055 DESCRIPTION WELDMENT CBS-2031e SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031e ONLY) SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031s ONLY) NUT, #4-40 KNURLED THUMB STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2" BOARD, POWER SUPPLY-120VAC BOARD, POWER SUPPLY-220VAC EXPORT 220V ONLY 29019 57006 57017 SPACE
15 16 17 17 17 18 19 20 20 1 1 2 1 1 1 7 13 1 1 52050 65002 86032 102189 52026 58054 83026 84002 102080 102158 TERMINAL BLOCK CONNECTOR, COPPER LUG BUSHING, SNAP, 1" MOUNTING HOLE DIA ASSEMBLY, POWER BRACKET, CBS-2000e CIRCUIT BREAKER, 5A SWITCH, PUSH BUTTON WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE, NUT, HEX, #8-32 MACHINE SCREW ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG. 5) ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG.
Figure 2 – CBS-2031e / CBS-2031s Tank Assembly DWG 104028-A ITEM # 1 QTY 1 PART # 004042 DESCRIPTION WELDMENT TANK CBS-2031e 2 1 24002 3 1 102013 4 3 31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD 5 3 83042 WASHER, .875"OD X .562"ID, FLAT 6 1 31081 PLUG, HEX HEAD 1/4" MPT 7 1 25098 FITTING, COMPRESSION MALE CONNECTOR 8 1 31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT 9 2 107025 HEATER ASSY., 1500W/120VAC 9 2 107019 HEATER ASSY.
8 84001 NUT, HEX, #6-32 MACHINE SCREW 17 1 31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD 18 1 83044 WASHER, 1.125"OD X 0.750"ID, FLA 19 1 31071 FITTING, 1/2 HOSE ID X 3/8" MPT 20 3 31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD 21 1 31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT 22 1 13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.
Figure 3 – CBS-2032e / CBS-2032s Main Assembly DWG 101196-D ITEM # 1 QTY 1 PART # 001050 DESCRIPTION WELDMENT, CBS-2032e 2 1 104027 3 1 22041 INSULATION TANK FRONT CBS-2032e 4 1 22042 INSULATION TANK BACK CBS-2032e 5 2 102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG 5) 5 2 102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG 5) 6 1 102189 6 1 52026 ASSEMBLY, TANK CBS-2032e (SEE FIG.
13 13 57047 1 13 13 102193 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) ASSEMBLY, HOT WATER VALVE, 220VAC 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) 57073 VALVE REBUILD KIT, DSV11.
6 4 1 1 1 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) 57073 83051 84030 57044 57047 57077 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM) WASHER, #8 SCREW SIZE, FLAT LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT VALVE, BYPASS LEFT 120 VAC VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) VALVE, BYPASS LEFT 220 VAC 57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER) 57073 101175 VALVE REBUILD KIT, DSV11.
Figure 4 – CBS-2032e / CBS-2032s Tank Assembly DWG 104027-A 20
ITEM # 1 QTY 1 PART # 4043 2 2 107021 3 1 31116 DESCRIPTION WELDMENT TANK CBS-2032e HEATER ASSY., 3000W/240VAC LOCKNUT 1/8 STRAIGHT PIPE THREAD 4 1 83041 WASHER, .812"OD X .
Figure 5 – Spray Housing Assembly, 120 VAC, Part # 102080 Spray Housing Assembly, 220 VAC, Part # 102158 (EXPORT ONLY) ITEM # QTY 1 2 4 1 2 3 4 5 6 1 1 1 1 1 PART # DESCRIPTION 82112 #8 X 3/4'' PAN HD. PHIL. T.S. 18-8 S.S. SCREW 57047 VALVE ASSY., DSV-11, 120 VAC 57071 57073 102082 24054 102081 VALVE ASSY., DSV-11, 240 VAC VALVE REBUILD KIT, DSV11 SPRAY HOUSING ASSY. O-RING 4.237” I.D., #156 SPRAY PLATE ASSY., 4 7/8" DIA.
NOTE: The round and square brew baskets pictured below are not interchangeable. Use only the type of brew basket that originally came with the brewer.