user manual

www.fetco.com
© 2003 Food Equipment Technologies Company
FETCO® and LUXUS® are trademarks or trade names of
Food Equipment Technologies Company. Part # P015 Rev. June 2, 2003
L3D-10
1 gallon
L3D-15
1.5 gallon
L3D-20
2 gallon
User’s Guide
L3D Series
Thermal Dispensers
IMPORTANT SAFEGUARDS
To prevent overflows, make sure the dispenser is completely
empty before brewing.
Always remove the funnel for manual filling of the dispenser.
Do not use bleach or cleaners containing chlorides.
Use only non-metallic brushes and cleaning pads.
Use only the handle to lift or carry the dispenser.
Do not use the faucet guard to pull or lift the dispenser.
Do not submerge the brew funnel.
CLEANING AND MAINTENANCE
Daily:
Important Notice: To maintain proper operation of the funnel
display, clean the funnel stem daily under running water with
detergent and a sponge or towel. Do not submerge.
Use any commercial beverage urn cleaner to clean the inside of
the dispenser. Follow the cleaner manufacturer’s instructions.
Make sure to thoroughly rinse the dispenser after cleaning.
Wash the drip tray and other plastic parts with dish detergent.
Avoid abrasives.
To sanitize the dispenser before filling, brew a batch of water only
(no coffee) into the dispenser and allow it to rest for 10 minutes.
Weekly, or as needed:
Remove the faucet upper assembly and inspect the seat cup for
wear. Clean or replace if necessary.
BREW FUNNEL DISPLAY
(Display updates every 6 seconds.)
Freshness Timer Volume Display
Timer is reset when dispenser is
completely emptied, when funnel is
removed, or when enough liquid is
added to increase the volume by at
least one level.
Examples for L3D-15:
Troubleshooting:
= 15 minutes.
= 1 hour.
- Each bar equals
¼
gallon.
- “V” section is 1
st
bar.
- Example shown is L3D-15.
L3D-10 has 4 bars.
L3D-15 has 6 bars.
L3D-20 has 8 bars.
15 minutes
Full
1 hour, 45 minutes
Half full –
¾
gallon
3 hours, 30 minutes
¼
gallon
Problem: “V” segment of volume display is
flashing slowly.
Cause: Funnel stem is dirty.
Solution: Clean funnel stem with detergent
and a s
p
on
g
e or towel.
Problem: Every other bar of volume display
is flashing slowly.
Cause: Battery power is low or internal
malfunction.
Solution: Replace with new funnel.
Battery cannot be replaced.
- flashing -
- flashing -
= Maximum time has
elapsed. (4 hrs.)
- flashing -
Closed
position
for serving
Open
position
for brewing
OPENING THE
DISPENSER
OPENING AND CLOSING
THE COVER PLUG
Squeeze tabs
together and lift.

Summary of content (2 pages)