Product Card

Prime Rating
These ratings are applicable for supplying continuous electrical power
(at variable load) in lieu of commercially purchased power. There is no
limitation to the annual hours of operation and this model can supply 10%
overload power for 1 hour in 12 hours.
Standby Rating
These ratings are applicable for supplying continuous electrical power (at
variable load) in the event of a utility power failure. No overload is
permitted on these ratings. The alternator on this model is peak
continuous rated (as defined in ISO 8528-3).
Standard Reference Conditions
Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m
(328 ft) A.S.L. 30% relative humidity.
Fuel consumption data at full load with diesel fuel with specific gravity of
0.85 and conforming to BS2869: 1998, Class A2.
Output Ratings Ratings and Performance Data
Marelli
Voltage, Frequency Prime Standby Engine Make & Model:
Alternator manufactured for
FG Wilson by:
Alternator Model:
Control Panel:
Circuit Breaker Type:
Engine Speed:
rpm
Base Frame:
Frequency: 50 Hz 60 Hz
Fuel Tank Capacity:
litres (US gal)
Dimensions and Weights
Length (L)
mm (in)
Width (W)
mm (in)
Height (H)
mm (in)
Dry
kg (lb)
Wet
kg (lb)
Dry = With Lube Oil Wet = With Lube Oil and Coolant
Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1.22.
Generator set pictured may include optional accessories.
www.FGWilson.com
//
//
Fuel Consumption: l/hr (US gal/hr)
(100% Load)
- Prime
DCP-10
Ratings at power factor.
Image for illustration purposes only.
- Standby
Available Options
FG Wilson offer a range of optional features to tailor our generator
sets to meet your power needs. Options include:
Upgrade to CE Certification
A wide range of Sound Attenuated Enclosures
A variety of generator set control and synchronising panels
Additional alarms and shutdowns
A selection of exhaust silencer noise levels
For further information on all of the standard and optional features
accompanying this product please contact your local Dealer or visit:
www.FGWilson.com
Heavy Duty Fabricated Steel
Please refer to the output ratings technical data section for
specific generator set outputs per voltage.
Perkins 1106A-70TAG3
MJB 250
MB4
400V, 50 Hz
480V, 60 Hz
180.0 kVA 144.0 kW 200.0 kVA 160.0 kW
200.0 kVA 160.0 kW 218.8 kVA 175.0 kW
P200-3
3 Pole MCCB
18001500
394 (104.1)
46.5 (12.3)39.8 (10.5)
50.6 (13.4)43.2 (11.4)
2510 (98.8) 1010 (39.8) 1640 (64.6) 1552 (3422) 1579 (3481)
0.8