Installation Guide

11
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222) www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
2.7 Installation niche features:
Brilliance-Integrated Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
899 / BI36: 902 mm (35 1/2”)
749 / BI30: 752 mm (29 5/8”)
Minimum Niche Depth
610 mm (24”) + panel thickness for flush install
Door Swing Clearance
899 /BI36: 1435 mm (56 1/2” in)
749 / BI30: 1285 mm (50 5/8” in)
Door Opening Angle
105°
Width
899 /BI36: 899 mm (35 3/8”)
749 / BI30: 749 mm (29 1/2”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door (without panel)
610 mm (24”)
Minimum distance from the wall (hinge side)
899 /BI36: 160 mm (6 1/4”)
749 / BI30: 125 mm (5”)
2. TECHNICAL REQUIREMENTS
EN
105°
560 (22”)
610 (24”)
899 / BI36: 899 (35 ⅜”)
749 / BI30: 749 (29 ½”)
10 (⅜”)
992 (39”)
899 / BI36: 1470 (57 ⅞”)
749 / BI30: 1320 (52”)
899 / BI36: 160 (6 ¼”)
749 / BI30: 125 (5”)
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2064 (81 ¼”)
899 / BI36: 902 (35 ½”)
749 / BI30: 752 (29 ⅝”)
610 (24”)
560 (22”)
1293 (50 ⅞” )
474
(18 ⅝”)
231 (9
⅛”
) +
25 (1”)
500 (19 ¾”)
248 (9
¾”
)
+ 25 (1”)
20 (¾”)
721 (28 ⅜”) +25 (1”)
2120 (83 ½”) +25 (1”)