Installation Guide

34
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
STANDPLUS AND X-PRO SERIES:
Ventilation is accomplished by a forced air sy-
stem through a grille located in the upper part of
the appliance. This grille should never be covered
by panels or any other devices that could reduce
its efficiency. Please refer to page 5-6 to ensure
correct air circulation.
7.4 Post installation control
Check that the front levelling feet have been pro-
perly installed.
Check that the connection to the water system
does not have any leaks and that the shut-o valve
is easily accessible.
Check that the electrical connection is correctly
installed and that the socket and / or breaker are
easily accessible.
Check the perfect alignment of the appliance
with adjacent structures.
7.3 Ventilation
INTEGRATED AND CLASSIC SERIES
A forced air system assures ventilation through a
grille positioned in the lower front part of the unit. If
the kitchen design includes a kickplate, it must be de-
signed to maintain a satisfactory air flow, as descri-
bed in the drawing below.
Holes can be in any shape and size, as long as the
total area of the area equals 50% of the kickplate
area.
In this case, to guarantee a better air flow, it is
advisable to remove the front grille included with
the unit. The grille is secured to the unit with
magnetic plates and can be easily removed even
by the end user, to provide for regular cleaning
procedures and dust removal.
The air intake and outlet must not be blocked
or covered entirely. The condenser must to be
dusted/cleaned on a regular basis so the custom
toe kick must accommodate this task.
SERIES 899
/ 36 ’’
SERIES 749
/ 30 ‘‘
SERIES 599 /
24 ‘‘
SERIES 449
/ 18 ‘‘
A 860 (33 7/8”) 710 (27 15/16”) 560 (22”) 410 (16 1/8”)
B > 100 (4”)
C 10 (3/8”)
A
B
C
C
100 (4”)