Installation Instructions

RECOMMENDED PROCEDURE
710088-100 Rev. B
Precast Shower Floors & Mop Basins
Installation Instructions – Terrazzo
Product names listed herein are trademarks of FIAT
© FIAT 2010
DO NOT STACK OR STORE TERRAZZO FLAT
MONTEREY SIERRA GIBRALTAR
REMOVE CRATE WITH CARE
RECOMMENDED
1/4" SPACE
BY FIAT
DO NOT DROP
ON PIPE
A. TAMP OAKUM TO 5/8" DEPTH
B. POUR MOLTEN LEAD
C. TAMP LEAD CAREFULLY
RECOMMENDED PROCEDURE
QDC CONNECTOR
A. INSTALL QDC CONNECTOR
B. TAMP QDC TO BOTTOM
C. TEST CONNECTION FOR LEAKS
D. SNAP STRAINER IN PLACE
REMOVE PIPE
FROM TRAP
REINSERT PIPE & TIGHTEN
WITH AN INTERNAL WRENCH
DOTTED AREA
IS FOR
SHOWER FLOOR
ADAT BASE INSTALLED IN PIT
For the Physically Challenged
DO NOT STAND ON END
LEVEL PRODUCT CAREFULLY
DO NOT LIFT SHOWER BY FLANGE
1. REMOVE CRATE AT INSTALLATION POINT. DO NOT ROCK TERRAZZO
ON EDGES IN ORDER TO PREVENT DAMAGES TO CORNERS.
2. CHECK ALL SIDES OF PRODUCT FOR TRANSPORTATION DAMAGES.
A: WIPE FACE OF THE TERRAZZO WITH A WATERED CLOTH.
B: AFTER WATER EVAPORATES, CHECK FOR CRACKS OR DAMAGE.
2A. ESTABLISH PROPER CLEARANCE BETWEEN UNIT AND WALL.
PLACE A 1/2" LAYER OF MORTAR WHERE THE SHOWER FLOOR IS
TO BE INSTALLED. THIS PROCEDURE IS REQUIRED BY FIAT
TO PROVIDE SUPPORT OF THE UNIT IN CASE THE SUB FLOOR IS
UNEVEN. LAYER OF GROUT SHOULD BE AT LEAST 1/4" THICK AND
COVER ENTIRE AREA UNDER THE UNIT.
2B. ADAT AND ADAW SHOWERS ARE FOR A.D.A. OR PHYSICALLY
CHALLENGED USE. THE SHOWER ENTRY SHOULD BE NO MORE
THAN 1/4" HIGHER THAN THE FINISHED FLOOR OF THE ROOM.
THE ADAT SHOWER SHOULD BE INSTALLED INTO A RECESSED
PIT 2 INCHES DEEP TO MEET CODE REQUIREMENTS.
2C. IT IS RECOMMENDED THAT A FLOOR DRAIN AT OR NEAR THE
ENTRANCE TO ALL ADAT, ADAW AND WTR SHOWER FLOORS
BE INCLUDED.
WARNING
WARNING:
MODELS WITH TILING FLANGE OPTIONS
3. DO NOT DROP UNIT OVER EXPOSED PIPE. IT IS ADVISABLE TO
REMOVE DRAIN PIPE AND SET UNIT IN PLACE. INSERT PIPE
THROUGH DRAIN IN FLOOR BACK INTO “P” TRAP.
TIGHTEN METAL CONNECTIONS WITH AN INTERNAL PIPE WRENCH.
IF USING PLASTIC WASTE PIPE, FIT AND SOLVENT WELD.
4A. METHOD OF DRAIN CONNECTION: METAL WASTE PIPE
USE OAKAM AND MOLTEN LEAD.
THIS LEAD CAULKED JOINT PERMITS LIMITED MOVEMENTS SUCH
AS NORMAL STRUCTURAL SETTLEMENT WITHOUT LEAKAGE.
5A. DO NOT LET ROUGH WALL MATERIAL OVERLAP FLANGE.
5B. DO NOT ATTACH FLANGE TO BUILDING.
5C. LET FINISHED WALL (TILE, ETC) OVERLAP AND REST ON SHOULDER.
4B. METHOD OF DRAIN CONNECTION: PLASTIC WASTE PIPE
WHEN USING PLASTIC WASTE PIPE , IT IS NECESSARY TO USE
THE QDC QUICK DRAIN CONNECTOR.
INSTALL PIPE THROUGH RECEPTOR.
LUBRICATE QDC CONNECTOR WITH SOAP, STRETCH QDC
CONNECTOR OVER PIPE WITH LETTERS FACING UP.
TAMP CONNECTOR WITH A HAMMER AND PIECE OF WOOD. WORK
AROUND CONNECTOR WITH A SERIES OF BLOWS UNTIL IT BOTTOMS.
TOP OF PIPE SHOULD BE EVEN WITH TOP OF CONNECTOR.
NOTE: FIAT PRODUCTS IS NOT RESPONSIBLE FOR SHOWER INSTALLATIONS
ADHERING TO A.D.A. GUIDELINES. CHECK LOCAL AUTHORITY FOR CODE
AND INSTALLATION REQUIREMENTS.
ADAT, ADAW, WTR
WHEELCHAIR ACCESS
MOP SERVICE BASIN
1/2" MORTAR
BED
GROUT
EXPOSED
SIDES
SUB FLOOR
1/4"
(6mm)
A. B.
D.
C.
STRAINER
PLATE
TEST
CONNECTIONS
FOR LEAKS
DRAIN
RECEPTOR
WASTE PIPE
A. B.
C.
A. B.
C.
LATH
PLASTER
BOARD
DO NOT ATTACH
FLANGE TO
TO WALL
TILE, ETC.
CAULKING
FAILURE TO INSTALL TERRAZZO ON A 1/2" MORTAR BED WILL VOID WARRANTY.
- 1 -