ADVANCED PARAMETERS
5. Automatic control - dimming step size
This parameter denes the percentage value of dimming step during
the automatic control.
Available settings: 1-99 - dimming step percentage value
Default setting: 1 Parameter size: 1 [byte]
6. Automatic control - time of a dimming step
This parameter denes the time of single dimming step set in param-
eter 5 during the automatic control.
Available settings: 0-255 (0-2.55s, in 10ms steps)
Default setting: 1 (10ms) Parameter size: 2 [bytes]
7. Manual control - dimming step size
This parameter denes the percentage value of dimming step during
the manual control.
Available settings: 1-99 - dimming step percentage value
Default setting: 1 Parameter size: 1 [byte]
8. Manual control - time of a dimming step
This parameter denes the time of single dimming step set in param-
eter 7 during the manual control.
Available settings: 0-255 (0-2.55s, in 10ms steps)
Default setting: 5 (50ms) Parameter size: 2 [bytes]
9. State of the device after a power failure
The Dimmer 2 will return to the last state before power failure.
Available settings: 0 - the Dimmer 2 does not save the state before
a power failure, it returns to „o position
1 - the Dimmer 2 restores its state before power
failure
Default setting: 1 Parameter size: 1 [byte]
10. Timer functionality (auto - o)
This parameter allows to automatically switch o the device after
specied time from switching on the light source. It may be useful
when the Dimmer 2 is installed in the stairway.
Available settings: 0 - Function disabled
1-32767 - time to turn o measured in seconds
(1s-9.1h)
Default setting: 0 Parameter size: 2 [bytes]