ADVANCED PARAMETERS
Available settings: 0 - detection of a burnt out bulb disabled
1-255 - delay time in seconds
Default setting: 5 Parameter size: 2 [bytes]
19. Forced switch on brightness level
If the parameter is active, switching on the Dimmer 2 (S1 single click)
will always set this brightness level.
Available settings: 0 - function disabled
1-99 - percentage level of brightness
Default setting: 0 Parameter size: 1 [byte]
GROUP 20 - Dimmer 2 operation - Switches
20. Switch type
Choose between momentary, toggle and roller blind switch.
Available settings: 0 - momentary switch
1 - toggle switch
2 - roller blind switch - two switches operate
the Dimmer 2 (S1 to brighten, S2 to dim)
Default setting: 0 Parameter size: 1 [byte]
21. The value sent to associated devices on single click
This parameter denes the value sent to devices associated with Dim-
mer 2 after its enabling.
Available settings: 0 - 0xFF value is sent, which will set associated
devices to their last saved state
1 - current Dimmer 2 state is sent, which will
synchronize brightness level of associated de-
vices (other dimmers for example)
Default setting: 0 Parameter size: 1 [byte]
22. Assign toggle switch status to the device status
By default each change of toggle switch position results in action of
Dimmer 2 (switch on/o) regardless the physical connection of con-
ntacts.
Available settings: 0 - device changes status on switch status
change
1 - device status is synchronized with switch
status
Default setting: 0 Parameter size: 1 [byte]