User's Manual

31
ADVANCED PARAMETERS
46. LOAD ERROR alarm report (no load, load failure, burnt out bulb)
Available settings: 0 - No reaction
1 - Send an alarm frame
Default setting: 1 Parameter size: 1 [byte]
47. OVERCURRENT alarm report (short circuit, burnt out bulb caus-
ing overcurrent)
Available settings: 0 - No reaction
1 - Send an alarm frame
Default setting: 1 Parameter size: 1 [byte]
48. SURGE alarm report (Dimmer 2 output overvoltage)
Available settings: 0 - No reaction
1 - Send an alarm frame
Default setting: 1 Parameter size: 1 [byte]
49. OVERHEAT (critical temperature) and VOLTAGE DROP (low volt-
age) alarm report
Available settings: 0 - No reaction
1 - Send an alarm frame
Default setting: 1 Parameter size: 1 [byte]
GROUP 50 - Active power and energy reports
50. Active power reports
The parameter denes the power level change that will result in a new
power report being sent. The value is a percentage of the previous report.
Available settings: 0 - power reports disabled
1-100 (1-100%) - power report threshold
Default setting: 10 (10%) Parameter size: 1 [byte]
52. Periodic active power and energy reports
Parameter 52 denes a time period between consecutive reports.
Timer is reset and counted from zero after each report.
Available settings: 0 - periodic reports disabled
1-32767 (1-32767 seconds)
Default setting: 3600 (3600s) Parameter size: 2 [bytes]