User's Manual

6
SUPPORTED LOADS
Supported load types 120VAC
Resistive loads
Conventional incandescent
and halogen light sources
25-125W
Resistive-capacitive loads
Fluorescent tube lamp (com-
pact / with electronic ballast),
electronic transformer, LED
25-100VA
Resistive-inductive loads
Ferromagnetic transformers
25-110VA
FIBARO Dimmer 2 uses dierent operating modes to control follow-
ing types of loads:
1. Trailing edge for resistive loads (R)
2. Trailing edge for resistive-capacitive loads (RC)
3. „Leading edge for resistive-inductive loads (RL)
NOTE
Some types of the LED
bulbs and compact
uorescent lamps are
designed to work in
leading edge operat-
ing mode.
i
Recommended values of power for supported loads: