User Manual

17
ADVANCED PARAMETERS
#12: Advanced parameters
1. Device orientation
Parameter determines orientation of the Swipe in relation to its de-
fault position. Required for proper gestures recognition.
Available settings: 0 - default orientation
1 - 180° rotation
2 - 90° clockwise rotation
3 - 90° counter-clockwise rotation
Default setting: 0 Parameter size: 1 [byte]
2. Buzzer - acoustic signal settings
Acoustic signalling of gestures detection.
Available settings: 0 - gestures detection is not signalled
1 - gestures detection is signalled
Default setting: 1 Parameter size: 1 [byte]
The Swipe allows to customize its operation to users needs. The set-
tings are available in the FIBARO interface as simple options that may
be chosen by selecting the appropriate box.
In order to congure the Swipe (using the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced” tab.
NOTE
Active acoustic signals
can be selected in
parameter 4.
i
Wake up interval
Available settings: 0 or 60-64800 (in seconds, 1min - 18h)
Default setting: 21 600 (every 6 hours)
The Swipe will wake up at each dened time interval and always try to
connect with the main controller. After successful communication at-
tempt, the device will update conguration parameters, associations
and settings and then will go into Z-Wave communication standby.
After failed communication attempt (eg. no Z-Wave range) the device
will go into Z-Wave communication standby and retry to establish
connection with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notication
to the controller automatically. Wake up may be still performed man-
ually using 1st menu position.
Longer time interval means less frequent communication and thus a
longer battery life