User Manual

20
ASSOCIATIONS
13. Rate of smooth level control
Parameter allows to choose how long the hand has to be held near the
center of the pad after "AirWheel" gesture for the associated devices to
reach their maximum/minimum level.
Available settings: 0-10 - duration in seconds
255 - default settings of controlled devices
Default setting: 255 Parameter size: 2 [bytes]
ASSOCIATIONS - CONTROL FRAMES CONFIGURATION
20. SWITCH ON control frame value for FLICK UP gesture
This parameter allows to set value sent in SWITCH ON command
frame to the association group.
Available settings: 0-99 or 255
Default setting: 255 Parameter size: 2 [bytes]
21. SWITCH OFF control frame value for FLICK UP gesture
This parameter allows to set value sent in SWITCH OFF command
frame to the association group.
Available settings: 0-99 or 255
Default setting: 0 Parameter size: 2 [bytes]
22. SWITCH ON control frame value for FLICK DOWN gesture
This parameter allows to set value sent in SWITCH ON command
frame to the association group.
Available settings: 0-99 or 255
Default setting: 255 Parameter size: 2 [bytes]
23. SWITCH OFF control frame value for FLICK DOWN gesture
This parameter allows to set value sent in SWITCH OFF command
frame to the association group.
Available settings: 0-99 or 255
Default setting: 0 Parameter size: 2 [bytes]
24. SWITCH ON control frame value for FLICK LEFT gesture
This parameter allows to set value sent in SWITCH ON command
frame to the association group.
Available settings: 0-99 or 255
Default setting: 255 Parameter size: 2 [bytes]
NOTE
Setting parameters
20-27 to appropriate
value will result in:
0 - turning o associ-
ated devices
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on
i
NOTE
Commands sent to
association group for
turn ON/OFF can be
adjusted in parame-
ters 20-27.
i