User's Manual

14
ADVANCED PARAMETERS
3. Visual LED indications
This parameter denes events indicated by the visual LED indicator.
Disabling events might extend battery life.
Available settings: 0 - no indications
1 - indication of opening/closing status change
(input IN)
2 - indication of wake up (1 x click or periodical)
4 - indication of device tampering
Default setting: 6 Parameter size: 1 [byte]
4. Range test after double click
Allows to enable activation of Z-Wave range test with double click of
a TMP button.
Available settings: 0 - disabled
1 - enabled
Default setting: 0 Parameter size: 1 [byte]
10. 2nd association group triggers
Parameter denes events which result in sending on/o commands
to devices added to the 2nd association group. These commands are
sent alternately to switch the devices on and o. Commands repre-
sent the values of BASIC SET command frames. Parameter is inactive
in external button mode (parameter 1 set to 1).
Available settings: 0 - switch after opening and closing
1 - switch after opening
2 - switch after closing
Default setting: 0 Parameter size: 1 [byte]
11. Commands sent to 2nd association group
Command frames sent to devices added to the 2nd association group.
Available settings: 0 - ON
1 - OFF
2 - ON & OFF
Default setting: 2 Parameter size: 1 [byte]
12. Value of ON command frame sent to 2nd association group
The value of 0 turns OFF the device, 255 turns it ON. In case of asso-
ciating the Dimmer or Roller Shutter module, values 1-99 allow to set
an associated device to a specied level.
Available settings: 0-99 or 255
Default setting: 255 Parameter size: 2 [bytes]
NOTE
Values of parameter
3 may be combined,
e.g. 1+2=3 means
opening/closing and
wake up will be indi-
cated by the visual in-
dicator.
i