ADVANCED PARAMETERS
72. Associations in Z-Wave network Security Mode
This parameter denes how commands are sent in specied associa-
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
network security mode. It does not apply to 1st group “Lifeline.
Available settings: 0 - none of the groups sent as secure
1 - 2nd group ”Control” sent as secure
2 - 3rd group ”Alarm” sent as secure
4 - 4th group “Sensor ZW3” sent as secure
8 - 5th group Tamper ZW3” sent as secure
Default setting: 15 (all) Parameter size: 1 [byte]
NOTE
Operating in Z-Wave
network security
mode automatical-
ly disables sending
alarms in broadcast
mode.
i
NOTE
Values of parameter
72 may be combined,
e.g. 1+2=3 means
2nd and 3rd group are
sent as secure.