confIguratIon
32. Alarm conguration - 3rd slot
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
signicant bytes are set according to the ocial Z-Wave protocol
specication.
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size 4B
Default value 0 (default)
Available
values
1B [MSB] – Notication Type
2B – Notication Value
3B – Event/State Parameters
4B [LSB] – action:
0x00 – No reaction
0x0X – Turn o selected channel
0x1X – Turn on the load
0x2X – Turn o the load
0x3Y – Load blinking
33. Alarm conguration - 4th slot
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
signicant bytes are set according to the ocial Z-Wave protocol
specication.
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size 4B
Default value 0 (default)
Available
values
1B [MSB] – Notication Type
2B – Notication Value
3B – Event/State Parameters
4B [LSB] – action:
0x00 – No reaction
0x0X – Turn o selected channel
0x1X – Turn on the load
0x2X – Turn o the load
0x3Y – Load blinking