User's Guide
19
ADVANCED PARAMETERS
29. S2 switch - scenes sent
This parameter determines which actions result in sending scene IDs 
assigned to them.
Available settings: 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key Hold Down and Key Released
Default setting:  0 Parameter size: 1 [byte]
30. S1 switch - associations sent to 2nd and 3rd association groups
This parameter determines which actions are ignored when sending 
commands to devices associated in 2nd and 3rd association group.  
All actions are active by default.
Available settings: 1 - ignore turning ON with 1 click of the switch
2 - ignore turning OFF with 1 click of the switch
4 - ignore holding and releasing the switch*
8 - ignore double click of the switch**
Default setting:  0 Parameter size: 1 [byte]
31. S1 switch - Switch ON value sent to 2nd and 3rd association 
groups
This parameter denes value sent with Switch ON command to devic-
es associated in 2nd and 3rd association group. 
Available settings: 0-255 - sent value
Default setting:  255 Parameter size: 2 [bytes]
32. S1 switch - Switch OFF value sent to 2nd and 3rd association 
groups
This parameter denes value sent with Switch OFF command to de-
vices associated in 2nd and 3rd association group. 
Available settings: 0-255 - sent value
Default setting:  0 Parameter size: 2 [bytes]
33. S1 switch - Double Click value sent to 2nd and 3rd association 
groups
This parameter denes value sent with Double Click command to de-
vices associated in 2nd and 3rd association group. 
Available settings: 0-255 - sent value
Default setting:  99 Parameter size: 2 [bytes]
NOTE
Setting parameters 
31-33, 36-38 to appro-
priate value should re-
sult in:
0  - turning o associ-
ated devices
1-99 - forcing level of 
associated devices
255 - setting associat-
ed devices to the last 
remembered state or 
turning them on
i
NOTE
Parameter 29 values 
may be combined, 
e.g. 1+2=3 means that 
scenes for single and 
double click are sent.
i
NOTE
Parameter 30 values 
may be combined, e.g. 
1+2=3 means that as-
sociations for turning 
ON and OFF are not 
sent.
i
NOTE
*Hold and release is 
inactive when param-
eter 20 is set to 1 or 2.
**Double click is inac-
tive when parameter 
20 is set to 1.
i