User's Manual

Fiber Cable
Jacket
Nut
Pressure Washer
Stopper
FC Connector
Bulkhead Strain
Relief Body
Enclosure Wall
Stopper Slit
Notes:
a) Unscrew large nut from bulkhead strain relief body.
b) Remove pressure washer and stopper from bulkhead.
c) Do not remove bulkhead strain relief body from enclosure.
d) Pass FC connector through nut and pressure washer.
e) Pull open slit in stopper, and pass fiber jacket to center of stopper.
Use care to prevent damage to fiber.
f) Seat stopper into bulkhead.
g) Adjust fiber to desired length inside enclosure by carefully
pulling fiber cable through stopper. Allow slight fiber slack
in enclosure.
h) Insert pressure washer into nut.
i) Tighten nut onto bulkhead body until fiber cable cannot move.
j) To prevent damage to fiber cable, do not overtighten nut. Snug
finger tight is sufficient to hold cable in place.
A
B
C
D
1
2
3
456
7
8
A
B
C
D
12
3
4
5
6
7
8
Size
A
Fiber-Span, LLC
1 Possumtown Road
Piscataway, NJ 08854
Units are inches unless
otherwise noted.
Tolerances as shown
unless noted:
Tol. Linear: X.XXX 0.005
Tol. Angle: 1
Material:
Date Created: 27-Mar-03
Rev
1
Dwg No.
CAGE
0Z4Y2
7010-0027
Drawn by: J. McSpiritt
Sheet 1 of 1
Procedure, Assembling FC Fiber
Connectors Through Bulkhead
Strain Relief Type 5540-6003
Third
Angle
Projection