12.4. On Site Requirements
For each RRU a three (3) wire (Hot, Neutral, and Ground) 120 VAC wall outlet including a
separate earth ground bus bar that connects to the unit chassis.
Two 9/125 um single-mode fiber strands with SC/APC connectors, one for the downlink path
and the other for the uplink path.
A unit as a simplex configuration requires two (2) high quality RF cable with N-Male connector
that attaches from the DAS to the RF Input and Output port.
A unit as a duplex configuration requires only one (1) high quality RF cable with N-Male
connector that attaches from the DAS to the bi-directional RF In/Out port.
13. General Precautions
Allow at least 6 inches of space into the air inlet and outlet of the unit, for proper air flow
through the fan(s).
Do not change any of the parameters unless instructed to do so by an authorized
supervisor and you are a qualified technician to operate device.
Do not attempt to move product without the proper tools and man power, because
product is heavy.
Terminate all the unit RF ports with a 50 Ohm load prior to powering up.
14. Maintenance
Periodically check and clean the unit fan(s) inlet and outlet by removing lint, dust and dirt with a
lightly damped cloth. Air-in-a-Can is also a good product to have as part of a maintenance kit
that includes an extended nozzle for hard to reach places.
Do not hose the unit with water as it is not waterproof.