User's Manual

Remote Fiber Node (RFN) User Manual
©Copyright 2011, Fiber-Span Page 29 of 38
Figure 23
Figure 24
14. Specifications
14.1. Electrical Specifications
Externally 3 wires (Hot, Neutral, Ground) conduit route through either
side (left / right) access panel orifice (Hot, Neutral) go to two in-line
breakers that connect to VAC In (range 85-265) power supply,
Outputting 28 Volt DC with 600 Watts capability providing power to all
the power amplifiers and in part regulated to 48 and 12 Volts for
discrete devices.
The Hot and Neutral wires connect internally to 2 in-line 1 pole 10 amp
circuit breaker (FS-Pn 760-0025 see Figure 23), mfr’s pn 1BU10 by
Altech Corp., that provides RFN protection.
Incoming external ground (GND) wire connects inside to a chassis
ground lug.
In the event primary power supply shuts off, as backup, design incorporates a second parallel
equivalent power supply so that the equipment will continue to operate without interruption.
Both breakers are DIN Rail mounted and
have the UL508 safety standard.
For recommended terminal connection to
the circuit breaker see Figure 24.
14.1.1. FS47R
Fully populated including WiMAX,
AC Current is 4.3 Amps / 120 VAC.
14.1.2. Plug-in
All VCC plug-ins are 28 Volts, except
FS42R-AP-3 which is 48 Volts. Figure 25
shows current for each plug-in.