Datasheet

FRC2
RELAY
FEATURES
High contact rating (50A)
High temperature design
Ideal for using in control-car starter and light
Plug in terminal
SPECIFICATIONS
COIL RATING
RATED
VOLTAGE
COIL
RESISTANCE
RATED
CURRENT
MUST OPERATE
VOLTAGE
MUST DROPOUT
VOLTAGE
MAXIMUM
VOLTAGE
POWER
( V DC) +/- 10 % (mA)
% OF RATED VOLTAGE
(
At +20
o
C
)
CONSUMPTION
6 20 300
12 80 150 65 Max. 10 Min. 130 Max. 1.8W (Approx.)
24 320 75
48 1280 37.5
* IF USE RESISTOR :
6VDC WITH 180 RESISTOR
12VDC WITH 680 RESISTOR
24VDC WITH 2702 RESISTOR
CHARACTERISTICS
Contact Arrangement 1 Form A; 1 Form C; 1 Form U ( = 2 x 1 Form A)
Contact Material Silvery Alloy
Contact Resistance
30m Max.
1A : 50A 14V DC
1C : (NO) 50A 14V DC (NC) 40A 14V DC
1U ( 2 x 1 Form A) : 2 x 25A 14VDC
Switching Voltage DC 75V
Operate Time (Initial) 7ms Max. Typical
Release Time (Initial) 5 ms Max. Typical
Insulation Resistance
100M Min. ( 500V DC)
Dielectric Strength 500Vrms between coil and contact
Shock Resistance 20g Approx.
Vibration Resistance 1.5mm Double amplitude 10-40Hz
Ambient Temperature
Operating : -40
o
C to +85
o
C Storage : -40
o
C to + 125
o
C
Humidity 40 - 85% RH
Mechanical : 10
7
Electrical : 10
5
Weight 35g Approx.
[Specifications are subject to change without notices.]
FORWARD INDUSTRIAL COMPANY.
(O/B COMMERCIAL UNION LTD)
RM. 1405, Wu Sang House, 655 Nathan Road, Mongkok, Kowloon, Hong Kong.
TEL : (852) 27892365 FAX : (852) 27893102 E-MAIL : sales@ficrelay.com.hk WEBSITE : http://www.ficrelay.com.hk
(At rated load)
Contact Rating (Resistive Load)
FRC2C