Datasheet

Power Relays
FRS1
Forward Industrial Company
Features
Small size and low cost
PCB mounting, DIL pitch terminal
Standard and high sensitive operation use
Dust cover or wash tight type
Low coil power consumption
Ordering information
FRS1 H - S 3 - DC12V
1 Relay model: FRS1; FRS1K (standard 5 pins)
2 Power consumption: NIL: 0.36W;
B : 0.45W (available with 5Amp);
H : 0.2W high sensitive
3 Construction: NIL Dust cover; S: Wash tight type
4 Contact rating: NIL: 1Amp; 2: 2Amp; 3: 3Amp;
5 : 5Amp (for “B” type only)
5 Rated voltage
Note: RoHS : RoHS compliant relay
RoHS-I : AgNi contact
RoHS-N: AgSnO contact
2
Coil rating
Rated
voltage
(V)
Coil
resistance
W+/-10%
Power
consumption
(W)
Approx.
Operate
time
(ms)
Release
time
(ms)
Must
operate
voltage
Must
dropout
voltage
Maximum
voltage
% of rated voltage (at 20°C)
3
5
6
9
12
24
20
56
80
180
320
1280
75 Max.
FRS1(K)B:
0.45
FRS1(K):
0.36
FRS1(K)H:
0.20
<5 <5
Characteristics
Contact arrangement SPST (1 Form A); SPDT (1 Form C)
Contact material Silver alloy (gold flash)
Contact resistance 50mW Max.
Contact rating (resistive) 1A 125VAC / 30VDC
2A 125VAC / 30VDC
3A 125VAC / 30VDC
5A 125VAC / 30VDC (only available for “B” type - 0.45W)
Switching voltage AC 220V / DC 60V Max.
Insulation resistance 100MW Min. (500VDC)
Dielectric strength 500VAC (50Hz/min) Between open contacts
500VAC (50Hz/min) Between coil and contact (Special: 1,000Vrms)
Shock resistance 10g Approx.
Vibration resistance 1.5mm Double amplitude 10-55Hz
Ambient temperature -25°C to +75°C
Operation life
7
10
5
10
Weight 4g Approx.
(Specifications are subject to change without notices.)
CAUTION: 1. The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2. Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Mechanical
Electrical
21 4
10 Min. 110 Max.
3
c us: E141516(N)
5
FRS1(K)B FRS1(K)
25
70
100
220
400
1600
45
120
180
400
700
2800
FRS1(K)H
Switching power 625VA / 150W Max.
Dimensions mm
Wiring diagram
(Bottom view)
FRS1
11
Mounting holes
Wiring diagram
(Bottom view)
Mounting holes
FRS1K
Reference data
505196
505188
505218
Conrad spezifische Daten sind gelb makiert!

Summary of content (1 pages)