Overview of Primary Product
sections describe the most common applications. The references 
to various series of control kits implies that any kit in that series 
may be used. Such as when a figure refers to a CK-60 series kit, a 
CK-60, 61, 62, etc. may be used. If further information or 
additional wiring diagrams are needed please consult Field 
Controls' technical support. 
I
NTERNAL WIRING CONNECTIONS FOR THE CAS UNIT 
Refer to Figure 3 for the internal wiring of the CAS-6/7 unit. 
E
XTERNAL WIRING CONNECTIONS 
Refer to Figure 4 for typical 120 VAC oil fired burner or Figure 5 for 24 
VAC gas fired burner connections that should be used when 
connecting the CAS unit. Refer to Figure 6 for connecting a single 120 
VAC appliance to the CAS, or Figure 7 for 24 VAC. The three wires 
“BURNER”, “WHITE”, and “ORANGE” in Figure 4 correspond to the same wires shown in Figures 6 & 10. The three wires 
labeled 1, 2, and 3 in Figure 5 correspond to the same wires shown in Figures 7-9. Refer to Figures 8-10 for connecting 
multiple appliances to one CAS unit. Note that an RJR-5 or RJR-6 relay and/or a CAC-24, CAC-120 or DIP-1 are required 
on certain multiple-appliance applications. Figure 11 shows how the pressure switch port on the CAC/DIP-1 should be 
attached to the CAS. Note that the correct 1/4" plastic tubing on the top of the CAS unit must be cut and a 3-way male 
barb TEE suitable for 1/4" tubing installed as shown in order to connect the CAC pressure port/DIP-1. 