TROUBLESHOOTING GUIDE
1. Do not wire the 24V models into the appliance 24 volt fan or thermostat circuit. This will cause premature
ballast or lamp failure and void the warranty. For proper operation, 24V models requires 24VAC at all
times.
2. Check to make sure 24VAC power is available at the transformer, or 120V at the electrical outlet.
3. If lamp does not light up, pull back metal washer on mounting base. If lamp comes on, the base needs
tightening to ensure that the safety switch is fully engaged.
4. If lamp does not light up, remove the ballast from the base and re-install it onto the base, ensuring that the
nger projecting from the base engages into the safety switch slot in the ballast. Repeat step 3.
5. If lamp does not light up after performing Steps 3 and 4, replace lamp.