Cascade Series Submittal

Page 1 of 2
P/N 780502000 07/22 Rev A
Cascade Series
CA2, CA3, CA4, CA5 Whole House Fans
ENGINEERING DATA
Air Health reserves the right to modify a product, without prior notice, whether in design, color or speci cations, in order to o er at all times a quality product that is
highly competitive. Please consult your national and local building codes to  nd out whether the installation of electrical products requires the services of a certi ed
technician or electrician. AirHealth and Cascade
TM
are registered Trademarks used under license by Air Health. All rights reserved.
ITEMS INCLUDED IN KIT
Fan assembly
7 feet of acoustically insulated  exduct
Gravity damper assembly
• Duct Adapter Assembly (as required)
White cube core inlet grille with fasteners
Wall Control for 1 or 2 speeds
• Instruction manual
• Installation hardware
DESCRIPTION
Cascade Whole House Fans are mechanical ventilation cooling systems. The occupant-controlled system allows for low temperature
outdoor air to be introduced in a home or building through open windows. The indoor air is circulated to cool the living space
and exhausted into the attic where it is then vented to the outdoors. Outdoor air will warm relative to the indoor temperature
and the low energy ventilation cooling fan is disengaged and windows closed.
FEATURES
CA Title 24 Listed
Galvanized Steel fan housing
Wall Mount 2-Speed Control
7 feet of insulated, noise reducing  exduct
• AirLoc
TM
R-5 Gravity Damper
All models designed to plug into 120 VAC, 15 amp,
dedicated power, standard wall outlet
Removable plaster guards
• Dramatic energy savings
• Permanent Split Capacitor (PSC) motors
• Ultra-quiet operation
• Easy installation
Heavy Gauge Material
PRODUCT OFFERING
Cascade Series with AirLoc
TM
Gravity Damper
Model
Fan Air ow
(GROSS)
CFM
HVI-916 std.
CA Title 24
(NET) CFM
Watts
CFM
per
Watts
Watts
per
CFM
Sound
Level
(dBA)
Speed
Control
Timer
Acoustical
Silencer
Duct
Rough
Opening
(inches)
Grille Size
(Inch x
Inch)
Damper
Blade
R-Value
Attic
Vent-
ing
(sq ft)
Open
Window
(sq ft)
Sizing 2
cfm/sqft
Sizing 1.5
cfm/sqft
Cascade CA2 2369 1932 295 6.55 .15 54 1 or 2spd 16"x 7ft 14.25x22.25 16 X 24 R-5 3.9 7.7
Cascade CA3 3339 2759 350 7.88 .13 53 1 or 2spd 18"x 7ft 14.25x22.25 16 X 24 R-5 5.5 11.0
Cascade CA4 4590 3640 430 8.47 .12 56 1 or 2spd 20"x 7ft 14.25x30.25 16 X 32 R-5 7.3 14.6
Cascade CA5 5902 4123 630 6.54 .15 59 1 or 2spd 20"x 7ft 14.25x30.25 16 X 32 R-5 8.2 16.5
ELECTRICAL REQUIREMENTS
VentCool
Models
Dedicated
Circuit
(Amps)
Voltage Watts
Motor
HP
CA2 15 120v 279 1/3
CA3 15 120v 341 1/3
CA4 15 120v 667 1/2
CA5 15 120v 781 1/2
DIMENSIONAL DATA
MODEL PART NUMBER
Cascade CA2 602603902
Cascade CA3 602603903
Cascade CA4 602603904
Cascade CA5 602603905
OPTIONAL ACCESSORIES
Digital Wall Timer/Temp Ctl w/ 602604201
RJ12 Cable includes FC3JF Fan Relay
Remote Timer/Temp Control 602604202
Includes AH-WTT Control Package
WiFi Module includes AH-WTT 602604203
Digital Wall Control Package
WiFi Switch Assembly includes 602604204
App, and FC3JF for Wireless install
Air Health Air Health
2630 Airport Road 9154 Stellar Court
Kinston, NC 28504 Corona, CA 92883
252 522-3031 951-277-0304
Fax: 1 (800) 367-7942
Visit us at: www.airhealth.com

Summary of content (2 pages)