Humidifier User Manual
2. WIRING  - Another important difference in the replacement of an “ESU” model with a new “S” 
series humidifier is the wiring connections. On the “ESU” the humidity control was connected to the
two ‘WHITE” wires on the molded plug. When upgrading to the “S” series, simply cut the two 
white wires and connect them to the two “H” terminals on the top of the front cover. 
The blower (fan) interlock was connected via the two red wires on the old “ESU” model and usually 
incorporated a field installed transformer and interlocking relay. Just cut the two red wires and 
connect them to the “R” and “G2” terminals on the top of the front cover. In this method you can 
reuse the field relay and transformer which were originally installed with the ESU.
If this is a new install then you can fully utilize the on board relay provided with the “S” series 
humidifier and interlock your blower “fan” by following the low voltage diagram. There is no need 
to install a separate transformer or relay.
DO NOT plug the molex connector  from the old “ESU”  humidifier,  into the socket on the side of
the front  cover on the new “S”  series humidifier.  That socket connection  is now reserved for the
automatic  drain  valve only. Doing so will damage  the unit  and void the warranty.
2
S2000 &  S2020 T ypical W ir ing
and B lower  I nter lock  Diagr am
 Furnace 
 S2000 & S2020 Humidifier
 Humidistat
G1 R G2 H H
Typical
Thermostat
G YWR
G YWR
H eat &  Cool System
Field Controls Humidifiers
AN-137 Replacement Instructions for
Models ESU14 & ESU20
SUPPLEMENT TO THE ELECTRONIC STEAM 
POWER HUMIDIFIERS MODEL #S2000 AND S2020