Product Overview
GSK Safety Switches
Introducing two new
• 160˚ activation
• Auto reset 
• 250˚ activation
• Manual reset 
GSK -160A 
for Draft Induced Furnaces
GSK -250M 
for Steam Boilers
  Models  Typical Applications
Our thermal safety switches efficiently detect flue 
gas spillage due to a blocked flue, continuous down 
drafting or inadequate draft condition. With the safety 
switch wired in series with the burner circuit, the switch 
will de-energize the system’s burner or burner control 
once it senses the spillage of hot flue gases. Available 
for gas-fired and oil-fired applications.
•FTS-4 & FTS-6
  Designed for use on large gas furnaces and boilers. Can  
  be mounted on Draft Hood or double-acting Barometric  
  Draft Control (both brackets included). Manual reset.
•SSK-1 & SSK-3
  Kit form of GSK-3 or GSK-4 generally used on millivolt  
  water heaters. Can also be used with 24 VAC gas    
  furnaces or boilers. Kit includes (2) GSK style Thermal    
  Safety Switches, (1) 12-gauge Jumper Wire and (1) 6 ft.  
  length 12-gauge lead wire. SSK-3 switches not supplied  
  with switch enclosures. TCA-1 or TCA-2 Thermocouple   
  Adapter required for 30 millivolt applications.
•WMO-1
  Designed for use with power venting and chimney vented  
  systems for oil-fired applications. Manual reset.
•GSK-160A & GSK-250M
  The GSK-160A is designed for use on draft induced    
  furnaces. Activates at 160˚. Silver Contacts. Auto reset.  
  The GSK-250M is designed for use on steam boilers.    
  Activates at 250˚. Silver Contacts. Manual reset.
•GSK-3 & GSK-4
  Designed for use on residential and light commercial    
  millivolt or 24 VAC gas furnaces, boilers and water    
  heaters. Generally used with sidewall venting applications.  
  Note: For 30 millivolt applications (residential water 
  heaters), a thermocouple adapter is required to connect 
  the GSK. The TCA is used to splice into the thermocouple 
  circuit. The TCA-1 has standard threads. The TCA-2 has 
  left handed threads for Flame Guard water heaters.
FTS
GSK
SSK
TCA
WMO
On Barometric Draft Controls and draft hoods 
to detect flue gas spillage and deactivate oil and 
gas burners.
The Thermal Safety Switch detects the increased 
heat generated by the flue gas spillage and 
deactivates the furnace or boiler. It will not allow 
the burner to restart until the switch has been 
manually reset.
When to use a Thermal Safety Switch
How Thermal Safety Switches Work
Improved safety for oil 
and gas appliances
NEW