Specification
Draft
Technical Service: 800.742.8368 • fieldcontrols.com 37
• To Provide Additional Air
A considerable amount of air is necessary to allow for
good chimney draft. In many tightly constructed homes,
this air is not readily available. The addition of a Type
C Draft Inducer will compensate for lack of air by
supplementing the chimney’s natural draft.
• To Create Draft in Cold Chimneys
A chimney, especially on an outside wall, may be so
cold prior to starting a fire that no draft exists. A Type
C Draft Inducer switched on before starting the fire will
provide draft until the chimney has become hot enough
to generate a natural draft.
• To Prevent Occasional or Continuous
Smoking
Occasional smoking may be the result of several factors
including downdraft caused by adjacent buildings, terrain,
or trees. Remodeling, new additions, or the addition of an
exhaust fan can change air flows and result in poor draft.
Or a fireplace design inadequacy, such as an undersized
flue, may prevent adequate draft.
The Type C Chimney Top Draft Inducer provides
negative pressure to overcome the effects of wind,
cold chimneys, insufficient chimney height, and
downdraft. The Type C Draft Inducer is effective
when venting standard fireplaces and freestanding
gas fireplaces.
The Type C Draft Inducer is available in four sizes:
6", 8", 10", and 13", and is designed to provide
years of trouble-free operation. It is insulated to
withstand peak temperatures up to 1300º F and
operates continually at 900º F without overheating
the motor windings or bearings. It can operate
with a standard manual on-off
switch, or can be installed with
the Field Controls variable
speed motor control.
When to Use a Chimney Top Draft Inducer
Stainless Steel
Construction
Chimney Top Draft Inducer
For Wood/Gas/Coal Fireplaces
Specifications
Motor Information Speed Control
Inducer Size Volts Amps Watts Hz RPMs
Max. Hearth
Opening
Volts Amps Hz
6" Type C
115 .81 57 60 1550 3.5 sq. ft. 115 5 60
8" Type C
115 .81 57 60 1550 7 sq. ft. 115 5 60
10" Type C
115 3.75 252 60 1050 12 sq. ft. 115 5 60
13" Type C
115 3.75 252 60 1050 30 sq. ft. 115 5 60
Dimensions
Model
Dimensions (inches)
Max. Hearth
Opening
A B C D
6" C Draft Inducer
5
59
⁄64 16 3
15
⁄32 14
3
⁄4 3.5 sq. ft.
8" C Draft Inducer
7
15
⁄16 16 3
3
⁄8 14
3
⁄4 7 sq. ft.
10" C Draft Inducer
10 16 3
3
⁄8 14
3
⁄4 12 sq. ft.
13" C Draft Inducer
13 16 3 14
3
⁄4 30 sq. ft.
Add FSGD 8 and 12, for gas and oil re. May need to add a single page and reduce the spread for
ClearWave to 1 page.
Optional Speed Control
for 6” & 8” or 10” & 13”
applications.