Specification
38 Customer Service: 252.522.3031
Draft
A
B
C
SPECIFICATIONS
ATAD LACIRTCELE)SEHCNI( SNOISNEMID TINU
MODELA BCDEVOLTSHzRPM HP AMPS THERMAL PROTECTION
8" DI 14 1/4819 1/217811560 1050 1/10 2.5 YES
12" DI 20 1/41219 1/2 21 12 115 60 1050 1/4 3 YES
D
E
Specifications
Electrical Data
Model Volts Hz RPMs HP Amps Thermal Protection
FSGD-8
120 60 1,050
1
⁄10 2.5 Ye s
FSGD-12
120 60 1,050
1
⁄4 3.5 Yes
Dimensions
Dimensions (Inches)
Max. Hearth Opening
(sq. ft.)
Model A B C D E
FSGD-8
14
1
⁄4 8 19
1
⁄2 17 8 12
FSGD-12
20
1
⁄4 12 19
1
⁄2 21 12 25
A
B
C
SPECIFICATIONS
ATAD LACIRTCELE)SEHCNI( SNOISNEMID TINU
MODELA BCDEVOLTSHzRPM HP AMPS THERMAL PROTECTION
8" DI 14 1/4819 1/217811560 1050 1/10 2.5 YES
12" DI 20 1/41219 1/2 21 12 115 60 1050 1/4 3 YES
D
E
The Flue Sentinel is designed with a hinged
cap so the fan, motor, and damper are easily
accessed for service or maintenance.
Chimney Fan with Damper
For Gas Fireplaces
Introducing the Flue Sentinel Chimney Fan with Automatic
Damper. This all-in-one includes a virtually air-tight
flue damper with a heavy duty fan and chimney cap
in one convenient, high performance package. The
unit eliminates the need for glass doors on a hearth to
conserve heat, and can save as much as 30% in energy
costs that would normally be caused by heat loss through
a chimney with a traditional damper.
The Flue Sentinel
®
Chimney Fan with Damper is
constructed of high-grade stainless steel and can be
installed in new or pre-existing chimneys. It is available in
two sizes for chimneys with 8” and 12” openings.
The Flue Sentinel
®
comes complete with a control kit that
interfaces with the gas logs and automatically opens the
damper and engages the fan before allowing the fire to
start. Back-up safety features ensure the fire won’t start
until the damper is fully open and draft has been proven.
Features
• Stainless steel housing
• Powder-coated, stainless steel chimney cap
• Two sizes: 8" and 12"
• Easy access for service
Benefits
• Integrated system for easy installation
• Reliable draft to exhaust fumes and gases
• Damper reduces heat loss and downdrafts
FSGD-8 Chimney Fan
with Damper
Flue Sentinel Gas Controller
(FSGC) Included