Specification
Technical Service: 800.742.8368 • fieldcontrols.com 7
Venting
Power Venter
Model
Extension Kit
Model
Maximum Wall
Thickness
SWG-4HD
PEK-4 12"
SWG-4HDS
PEK-4 12"
SWG-5
PEK-5 16"
SWG-5S
PEK-5 16"
SWG-6
PEK-6 16"
SWG-6S
PEK-6 16"
SWG-8
PEK-8 16"
* Control Kits are ETL approved accessories when used in conjunction with the SWG Power Venter.
** Plugs into 24v electric damper
*** A secondary safety switch should be used with a CK-81
F = Fixed Post Purge FV= right hand threaded TCA Safety Switch
CK-62 mounted at venter. For use with a 24
VAC, gas-fired system (shown with cover off).
CK-63 remote mounted. For use with 120V or 24V oil or gas
systems. Electronic post purge is included (shown with cover off).
Control Kit Installation
Control Kit*
Control Kits (CK) control the operation of SWG/
CV Power Venters. See the chart below to select
the proper kit for your application. Control Kits can
also control the operation of Field Draft Inducers.
NOTE: CK kits can be mounted up to 100 feet from venter.
Required to Operate SWG/CV Power Venters
Control Kits
Selecting the proper Control Kit for your application
Draft Proving Switch
Gas Pressure Switch
Secondary Safety
Switch
Thermal Post Purge
Adjustable Electronic
Post Purge
Fixed Post Purge
Draft Control
RJR-6
Model Applications
Oil
CK-61
All oil-fired systems. Has adjustable electronic post purge.
3 3 3 3
CK-62
All oil-fired systems. Has thermally activated post purge.
3 3 3 3
CK-63
All oil-fired systems. (May require optional delay oil valve for simultaneous
burner operation.)
3 3 3
Gas
30 mv
CK-20FV
30 millivolt gas-fired water heaters and gas-fired pool or spa heaters with
a manual or internally mounted thermostat.
3 3 3
CK-21
Gas-fired instantaneous water heaters with pressure tap port in the burner
manifold.
3 3
24 v
CK-41F
CK-41P**
Furnaces, boilers, unit heaters and water heaters operating with a 24 VAC
gas valve without factory mounted spillage switches.
3 3 3
CK-43
Draft induced 24 VAC gas valve systems. Includes a 4" MG-1 draft control
and post purge.
3 3 3
CK-43F
3 3 3
750 mv
CK-81***
750 millivolt operated boilers, furnaces, water heaters, pool or spa heaters
and gas-fired fireplaces when operated with a remote mounted thermostat
or on/off switch. Operated off a 24 VAC circuit.
3 3
CK-21
750 millivolt operated gas-fired appliances with pressure tap port in the
burner manifold.
3 3
Co-venting Multiple
Appliances
CK-91FV
Gas-fired draft induced 24 VAC gas valve systems and a 30 millivolt
operated water heater. Includes a 4" MG-1 draft control and post purge.
3 3 3 3 3
CK-92FV
CK-92FVP**
Gas-fired furnace or boiler and a 30 millivolt operated water heater.
Includes post purge.
3 3 3 3