WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
MODEL
LAMP
(Field Controls Part Number)
CIRCUIT BOARD
(Field Controls Part Number)
BALLAST
(Field Controls Part Number)
UV-12C 46365401 46436300 4 6 36 5511
UV-18C 46365402 46436300 46365512
UV-28C 46365403 46436300 46365510
UV-28 46365403 N/A 46365503
UV-12HP 46365401 N/A 4 6 36 5511
UV-18HP 46365402 N/A 46365512
UV-28HP 46365403 N/A 46365510
UV-12HPC 46365401 46436300 4 6 3 65 511
UV-18HPC 46365402 46436300 46365512
UV-28HPC 46365403 46436300 46365510
TROUBLESHOOTING GUIDE
If the LED is illuminating a YELLOW color and the circuit board alarm beeps every 15 minutes, the lamp 1.
should be replaced soon.
If the LED is illuminating a RED color and the circuit board alarm beeps every 5 minutes, the lamp should 2.
be replaced immediately.
If the lamp does not light up, replace lamp.3.
If the lamp still does not light up after replacing the lamp, replace ballast. 4.
REPLACEMENT PARTS LIST
For replacement parts, contact your local heating service company.
Any questions, please contact Field Controls at:
•Phone:252-522-3031•Fax:252-522-0214•Email:sales@eldcontrols.com
NOTE: UV lamps contain a small amount of mercury, like
atypicaluorescentlamp.Checkwithyourlocalwaste
management authority for local disposal or recycling
requirements. According to the EPA's Universal Waste Rule,
these types of lamps may be disposed of into household waste.
Insert the lamp through the mounting hole and secure the 5.
lamp by rotating the swivel bracket counter-clockwise into
position and secure by tightening wing nut. Be careful not to
over tighten the wing nut.
Attach ballast plug onto the end of the lamp.6.
Plug in the power cord and press the power switch to the 7.
ON position.
Press the timer reset button on the circuit board using the eraser end of a pencil or the blunt end of a 8.
plasticinkpen.Holdforthreeseconds.(SeeFigure22)
Releasethetimerresetbutton.TheLEDonthecoverwillashtwice,indicatingthetimercircuithas 9.
been reset.
Close cover and tighten cover screw.10.
Afterreplacinglamp,makesureanewLampReplacementLabel(suppliedwithlampreplacement)is11.
applied to the housing and dated with the date of installation.
Figure 22