Brochure

page 5
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Figure 3 Figure 4
Figure 5 Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or a.
horizontalposition.(SeeFigures2B&3)
Bend tabs outward as shown in Figure 4.b.
Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a c.
template.(SeeFigure5)
Removethecutpieceofduct.(SeeFigure6)d.
Bendbothtabsdownandthroughductatrstbendpoint.(SeeFigures7&8)e.
Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct f.
material.(SeeFigures9&10)
Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. g.
(SeeFigure11)
IF YOU HAVE DUCT BOARD: