WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Swing the swivel bracket over the end of lamp. Hand-tighten the 9.
wing nut on the stud. Be careful not to over tighten the wing nut. The
porcelain at the lamp base may crack when over tightened.
(SeeFigure17)
Plugballastplugintoendoflamp.(SeeFigure18)10.
Snapcoverontotheunitbase.(SeeFigure19)11.
PlugtheLEDwirefromthecoverontotheboard.(SeeFigure20)12.
Closethecoverandtightencoverscrew.(SeeFigure21)13.
Plug the power cord into a standard electrical outlet.14.
NOTE: Seal the joints and seams of the plenum near the mounting location
toreduceanydirectviewingoflight.(SeeFigure1)
PressthepowerswitchtotheONposition.(Lightonswitchshouldbe15.
on,indicatingpower.)
Look through view port in the box cover to be sure the lamp is working. 16.
Youshouldseeablueglow.(Theviewportiscoveredwithaplastic
lensthatblockstheUVCrays.)Ifequipped,theLEDlightwillshowa
continuous GREEN color indicating proper unit operation.
If the lamp is not glowing, follow steps 8-14 again. If lamp still does 17.
notglow,contacttechnicalsupportat252-522-3031forfurther
assistance.