Humidifier User Manual
ULTRA-ZONE HUMIDIFIER
 Z100 ASSEMBLY
INSTALLATION INSTRUCTIONS & OWNER'S MANUAL
Z100 REPLACEMENT INSTRUCTIONS
SUPPLEMENT TO THE ULTRA-ZONE ELECTRONIC STEAM POWER HUMIDIFIERS 
MODEL # S2000 AND S2020
 AN 131 
The ULTRA-ZONE steam humidifier now comes equipped with a factory installed Z100, which acts as a 
sacrificial metal. Put simply, the chemicals in the water will attack and cling to the  . The chemicals 
will not attack the other components inside the humidifier as long as the  Is active.
This results in a dramatic decrease in chemical and scale build up on the stainless steel components 
inside the tank. In particular, it means less scale build up on the heating element which is subject to 
damage from excessive scaling and over heating. This also means that efficiency stays high and
preventive maintenance is   and  .
The   is positioned on the baffle plate inside the tank and is easily removed and replaced. 
Remember that the  ’s job is to become the target of chemical attack, so it will be heavily covered 
with scale and should be replaced annually for best results.
To remove the   you must have already unplugged and shutdown your steam humidifier and 
allowed it to cool. The water tank has been drained, the water supply, drain lines and electrical wiring
have been disconnected and the unit has been removed from the duct. 
Using a phillips screwdriver, remove the two screws that hold the baffle plate to the tank. Lift the baffle 
slightly back to clear the water probe and then straight up and out of the tank. You can then see the 
round  , or rather what is left of it after a single season. Notice the heavy scale build up on the   
that would have been on your element, if the   was not there. Use a rag or pliers to grasp the edges 
of the   and simply unscrew it from the baffle plate. Rinse off or wipe away any residual scale from 
the baffle plate and install the new  . Leave a slight gap between the bottom of the  and the 
baffle plate. Now re-insert the baffle plate into the tank and secure with the two screws that were 
removed previously. It’s that simple.
The  can also benefit the older model steam humidifiers. Simply lay the  down into the baffle 
plate in the same location as the factory installed model. DO NOT lay the  down into the main 
tank. It may come in contact with the heating element and damage it. The dimensions of the baffle 
plate prevent the  from falling down into the tank.
The Z100 is just the latest innovation in the ULTRA-ZONE Steam Humidifier line as we continue in our 
pursuit of Excellence Without Compromise. 
Z100
Z100 
faster easier
Z100
Z100
Z100
Z100 Z100
Z100
Z100
Z100 Z100 
Z100 Z100 
Z100 
Z100 
EWC Controls Inc. 385 Highway 33   Englishtown, NJ 07726 800-446-3110   FAX 732-446-5362 E-Mail- info@ewccontrols.com
P/N 090376A0131 REV. B COPYRIGHT © 2002-2006, EWC Controls Inc., All Rights Reserved
Field Controls Inc.  2630 Airport Road Kinston, NC 28504 PH: 252.522.3031 FAX: 252.522.0214
P/N 090376A0131  REV. C  10/2011               Copyright © 2011, Field Controls Inc.,  All Rights Reserved
The Field Controls Steam Humidifier now comes equipped with a factory installed Z100, which acts 
as a sacrificial metal. Put simply, minerals in the water will attack and cling to the Z100. The 
minerals will not attack the other components inside the humidifier as long as the Z100 is present 
and active.
This results in a dramatic decrease in mineral and scale build up on the critical components inside 
the tank. In particular, it means less scale build up on the heating element which is subject to 
damage from excessive scaling and over heating. This also means that efficiency stays high and 
preventive maintenance is faster and easier.
The Z100 is positioned on the baffle plate inside the tank and is easily removed and replaced. 
Remember that the Z100ʼs job is to become the target of mineral attack, so it will be heavily 
covered with scale and should be replaced annually for best results.
To remove the Z100 you must have already unplugged and shutdown your steam humidifier and 
allowed it to cool. The water tank has been drained, the water supply, drain lines and electrical 
wiring have been disconnected and the unit has been removed from the duct.
Refer to the blow up view on Page 11. Using a phillips screwdriver, remove the two screws that 
hold the baffle plate to the tank. Lift the baffle slightly back to clear the water probe and then straight 
up and out of the tank. You can then see the round Z100, or rather what is left of it after a single 
season. Notice the heavy scale build up on the Z100 that would have been on your element, if the 
Z100 was not there. Use a rag or pliers to grasp the edges of the Z100 and simply unscrew it from 
the baffle plate. Rinse off or wipe away any residual scale from the baffle plate and install a new 
Z100. Leave a slight gap between the bottom of the Z100 and the baffle plate. Now re-insert the 
baffle plate into the tank and secure with the two screws that were removed previously. Itʼs that 
simple.
The Z100 can also benefit the older model steam humidifiers. Simply lay the Z100 down into the 
baffle plate in the same location as the factory installed model. DO NOT lay the Z100 down into the 
main tank. It may come in contact with the heating element and damage it. The dimensions of the 
baffle plate prevent the Z100 from falling down into the tank.
SUPPLEMENT TO THE ELECTRONIC STEAM 
POWER HUMIDIFIERS MODEL #S2000 AND S2020