User Guide

01 02 03 04 05
Maintenance
CLEANING: Clean the exterior with a damp
cloth. Do not use detergents or solvents. Do not
apply pressurized air into the connection port.
BATTERIES: When the LED slow-blinks Red,
the batteries must be replaced. Ensure the
power is OFF. Remove the single screw from the
yellow battery cover. Install 2 x AAA batteries.
You can also monitor battery life in the Job Link
app tool manager.
SENSOR CARE: Store JL3MN in a protective
cover when not in use to prevent debris or
foreign contaminants from entering the barb
tip. Do not pressurize the probe above its max
specication.
Specifications
Minimum Device Requirement:
BLE 4.0 devices running iOS® 7.0 or Android™ 5.0
(Latest compatibility at www.eldpiece.com)
Compatible Media: Dry, non-corrosive gas
Pressure Port: Tube connector for exible tubing (4.5 to 8mm ID)
Units of Measure: inWC, mmWC, mbar, psi, Pa
Accuracy and Ranges:
inWC: ±0.02 on 0.00 to ±2.00 (±1.5% FS on 2.00 to ±60.00);
mmWC: ±0.5 on 0.0 to ±51.0 (±1.5% FS on 51.0 to ±1500.0);
mbar: ±0.05 on 0.00 to ±5.00 (±1.5% FS on 5.00 to ±150.00);
psi: ±0.001 on 0.000 to ±0.072 (±1.5% FS on 0.072 to ±2.165);
Pa: ±5 on 0 to 498 (±1.5% FS on 498 to ±14930)
Maximum Overload Pressure: 321.08 inWC (11.6 psi; 80.0 kPa)
Battery Type: 2 x AAA, NEDA 24A, IEC LR03
Battery Life: 150 hours typical alkaline. LED slow-blinks red when
battery replacement is needed.
Auto Power O: 2 hours (APO can be disabled)
Wireless Range: 350 feet (107 meters) line of sight.
Obstructions aect distance.
Radio Frequency: 2.4 GHz
Operating Environment: -10°F to 122°F (-23°C to 50°C) at <75%
RH
Storage Temperature: -10°F to 140°F (-23°C to 60°C) at <80% RH
(with batteries removed)
Temperature Coecient: 0.1 x (specied accuracy) per 1.8°F
(-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to
50°C)
Weight: 0.30 lbs (137 g)
Quick Start
1 Install the Fieldpiece Job Link® System app on
your mobile device and sign up for an account
if you're a new user.
2 Remove the single screw of the yellow battery
cover and install 2 x AAA batteries.
3 Press for 1 second to power on.
4 Open Measurements in the Job Link app and
favorite the probe in the tool manager.
5 Tap to zero.
6 View live measurements on your mobile
device up to 350 feet (107 meters) away.
What's Included
Job Link® System Manometer Probe
2 x AAA Batteries
Tubing with brass tting
Bulk tubing
Gas adapter
Static pressure tip
Operator's manual
1 Year limited warranty
Description
The JL3MN Job Link® System Manometer
Probe sends static pressure or gas pressure
measurements directly to the Fieldpiece Job
Link app up to 350 feet (107 meters) away.
Use two JL3MN probes to do even more.
Because they are untethered, you don't need
long hoses to measure dierential pressures.
Measure and view real-time return static,
supply static, and total external static pressure
all at once. Use your static pressure tip with
short tubing for accurate static pressure
measurements. Measure real-time inlet and
manifold pressures simultaneously with 2 Job
Link manometers.
Mount your manometer to equipment for
hands free use in tight spaces. The powerful
rotating magnet holds tight even when the hose
is tugged or the equipment shakes. Slide the
switch and the app immediately knows which
side of the system you're going to place your
manometer probe.
WARNING
Prevent damage, do not drill holes blindly into a plenum that
houses the evaporator or heat exchanger.
Do not place any part of the manometer on hot surfaces such
as exhaust fumes. Doing so can cause personal injury, damage
equipment, and void warranty.
Do no apply more than 11.6 psi.
Job Link® System
Manometer
Probe
OPERATOR'S
MANUAL
Model JL3MN