User Guide

More Products From Fieldpiece
Modular Expandability
Modular expandability is ability for accessory
heads and meters to change configurations to
match the various needs of an HVAC/R technician.
Accessory heads (the sensors) send out a mV
signal, which represents the value of the measure-
ment, to whatever meter is attached to it. Heads can
attach directly to the top of a Stick meter, DL3 data
logger, or EHDL1. They can also plug into any meter
with mV ranges using ADLS2 leads.
Stick Meter
This is the heart of modular expandability. In addi-
tion to being a full functioning multimeter, any acces-
sory head can be used with it.
Model HS36
True RMS
Non contact voltage
Magnetic hanger
Autoranging
Backlight
Microamps
Temperature
Volts, amps, ohms
Frequency
Microfarads
Includes:
HS36 Meter
ACH4 Current Clamp
ATB1 K-type T/C
ADK7 Deluxe Leads
ANC1 Case
Accessory Heads
Accessory heads are the sensors of multiple
parameters measured by technicians every day.
They plug into a mV range (depending on the head)
of a multimeter. The multimeter will display whatev-
er the head is measuring. Instead of having to pur-
chase and carry a separate instrument for each
parameter, a technician may use multiple heads and
a single multimeter to do the job.
Here are four of the many heads available:
AAV3 Air Velocity and Temperature
ADMN2 Dual-Port Manometer
AVG2 Digital Vacuum Gauge
AOX2 Combustion Check
Warranty and Service
The product is warranted to the original purchas-
er against defects in material or workmanship for a
period of one (1) year from the date of purchase.
During the warranty period, Fieldpiece Instruments
will, at its option, replace or repair the defective unit.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranty arising out of the sale of
Fieldpiece's products including but not limited to
implied warranties of merchantability and fitness for
purpose are limited to the above. Fieldpiece shall
not be liable for incidental or consequential dam-
ages.
Contact Fieldpiece for an RMA# if returning any
defective SRL8 for warranty service. Include the
defective instrument along with proof of purchase.
Contact Fieldpiece for out of warranty repair
charges.
Fieldpiece Instruments, Inc.
California, U.S.A.
www.fieldpiece.com
Air Velocity
& Temperature
Head
English
READLO BATT
ON
LCD X
100
Average
(16 sec)
Metric
Real
time
AAV3
AUTO-
OFF
English Metric
Ft/min M/s
KM/hrMPH
ºF ºC
OFF
ADMN2
Dual-Port
Manometer
Accessory
Head
P1
P2
P1-P2
ON
0.1
ENGLISH
METRIC
0.01
(LCD/10)
Lo Batt
Resolution
ZERO
AUTO
OFF
P1 P2
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
AOX2
Combustion
Check
%O
%CO
TEMP
ON
GAS
OIL
Lo Batt
°C °F
AUTO
OFF
STABLE
Fuel Type
2
2
T/C
CAL
v12
Lithium Battery Care
The SRL8 contains a very powerful lithium ion
battery. For a long battery life and safe operation,
you must observe the following:
Cautions
1. Do not expose the battery to temperatures high-
er than 140ºF (60ºC).
2. Do not charge the battery in or near heated
places such as fire, hot vehicles, or direct sun-
light.
3. Do not solder directly on battery.
4. Do not expose the battery to direct impact or
throw it.
5. Do not get the battery wet.
6. Do not deform or pierce the battery in any way.
7. If there is any battery leakage, do not touch the
battery. In the case that electrolyte gets into the
eyes, flush with fresh water, do not rub, and see
a physician immediately.
8. Send in for replacement immediately if there is
any deformity, bad smell, color change, or other
abnormality.
9. The battery is user-replaceable and can be pur-
chased at most electronic stores. The following
batteries are compatible with the SRL8: Fuji
Film: NP-120, PENTAX: DLI-7, RICON: DB-43
Charging
Two chargers are included with the SRL8. The
AC charger plugs into a wall outlet, and the car
charger plugs into a car cigarette lighter DC plug.
1. The battery is partially charged when packaged.
Fully charge the battery before first use.
2. The LOW-BATT LED will light red when the bat-
tery is low. Charge can be checked at any time
the unit is on with the Battery Check function
(See Operation section).
3. To recharge the SRL8, plug one end of the
charger into the top of the SRL8 and the other
into the power source. LOW-BATT will blink
while charging until the battery is fully charged.
When the SRL8 battery is fully charged, LOW-
BATT turns off.
4. Charge within operating environment specified
in the Specifications section of this manual.
5. Avoid frequent full discharges. Several partial
discharges with frequent recharges are better
for lithium-ion batteries. Unlike nickel-based bat-
teries they have no charge memory and do not
need to be discharged before charging.
Storage
The battery should have a 40%-50% charge dur-
ing prolonged storage of a month or longer. See
Specifications section of this manual for proper stor-
age environment.
Battery life is dramatically reduced if the battery
is stored fully charged and/or at high temperatures.
Filter Assessment & Replacement
The filter blocks moisture and other contami-
nants from the sensor. When it gets wet, it con-
stricts flow of air, and the filter will have to be
replaced. Unscrew the sensor tip and replace the
white filter so that the rounded end is closest to
the tip of the wand. Use only the Fieldpiece sup-
plied filter.
You can order from a distributor extra bags of
replacement parts (model RFL2) are available
from Fieldpiece. Model RFL2 contains 10 filters
and 5 O-rings.
Installing and Replacing Sensor
Replacement sensors (model RHD1) can be
ordered for the SRL8. To install or replace the sen-
sor, make sure the unit is turned off. Then, simply
unscrew the snoot on the SRL8 and if replacing
gently pull the sensor from the base. WARNING:
the sensor may be hot after use. Carefully insert
the new sensor and replace snoot. The sensor can
be inserted in two different configurations, either of
which will allow the SRL8 to function correctly.
If no sensor is installed or the installed sensor is
broken when the unit is turned on an alarm will
sound and the unit will turn off.
Included Equipment
Use model RRE2 when detecting in tight spaces,
such as through a condenser grille. Model RFE2
extends the wand to 25.5”. The blow molded case,
model holds accessories and chargers.
All accessories shown are included with the
SRL8.
9” Flex Extension
model RFE2
Blow Molded Carrying Case
w/ RRE2 and RFE2
Model ABMK3
Sensor model
RHD1
9” needle tip
model RRE2