A Sierra Monitor Company Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-72 Secutron Modul-R APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after August 2008 Driver Version: Document Revision: 1.
FS-8700-72 Secutron Manual Table of Contents TABLE OF CONTENTS 1. 2. SECUTRON MODUL-R DRIVER DESCRIPTION ...........................................................3 DRIVER SCOPE OF SUPPLY.........................................................................................3 2.1. Supplied by FieldServer Technologies for this driver.................................................. 3 3. 4. HARDWARE CONNECTIONS ........................................................................................
FS-8700-72 Secutron Manual 1. Page 3 of 15 Secutron Modul-R driver Description The Secutron Modul-R driver allows the FieldServer to transfer data to and from a Client and a Server panel on a single point to point network over RS-232 using Secutron Modul-R protocol. The protocol is strictly command/response with the Client polling a Server device. A Server device can report the generation and clearing of alarms to the polling Client. One panel can be connected per FieldServer port.
FS-8700-72 Secutron Manual 3. Page 4 of 15 Hardware Connections The FieldServer is connected to the panels as shown below. Configure the panels according to manufacturer’s instructions. Connector Pinouts RJ-45 Pin From RJ-45 1 Brown 8 White/Orange 5 Blue/white To Secutron Tx Rx GND FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Free: 888-509-1970 email: support@fieldserver.
FS-8700-72 Secutron Manual 4. Page 5 of 15 Configuring the FieldServer as a Secutron Modul-R driver Client For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files on the provided with the FieldServer).
FS-8700-72 Secutron Manual 4.2.
FS-8700-72 Secutron Manual 4.4. Page 7 of 15 Client Side Map Descriptors 4.4.1.
Function must be read for pollers and all others Passive_Client. Data_Array_Offset, 0, 0, 0, 0, 0, 0, 0, Secutron_Type, poller, device, function, device, function, device, function, The type of data the Map Descriptor points to. Device data contains alarm statuses. Function data contains condition codes. Refer to Appendix A.1 for more information. Node_Name, Node_1, Node_1, Node_1, Node_1, Node_1, Node_1, Node_1, A name given to the device to which the FieldServer is connected.
FS-8700-72 Secutron Manual 5. Page 9 of 15 Configuring the FieldServer as a Secutron Modul-R driver Server For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files provided with the FieldServer).
FS-8700-72 Secutron Manual 5.2.
FS-8700-72 Secutron Manual 5.4. Page 11 of 15 Server Side Map Descriptors 5.4.1.
Function may not be read or write since it implements a Server. Function may only be Server. Data_Array_Offset, 0, 0, 0, 0, 0, 0, Secutron_Type, device, function, device, function, device, function, The type of data the Map Descriptor points to. Device data contains alarm statuses. Function data contains condition codes. Refer to Appendix A.1 for more information. Node_Name, Node_1, Node_1, Node_1, Node_1, Node_1, Node_1, A name given to the device to which the FieldServer is connected.
FS-8700-72 Secutron Manual Page 12 of 15 Appendix A. Advanced Topics Appendix A.1.
FS-8700-72 Secutron Manual Appendix A.2. Page 13 of 15 Panel Circuit or Zone numbers The panel groups events under circuit or zone numbers. When setting up a Client configuration it is necessary to create Map Descriptors to trap the events from the zones or circuits you want to see data from. If an event is received that has no corresponding Map Descriptor defined, this will be reported on the RuiNet E screen. This is a useful configuration tool to ensure that all required data is stored.
FS-8700-72 Secutron Manual Appendix A.3. Page 14 of 15 Panel Power-up, Restarts and Resets When the panel powers up or is restarted it will send an event on zone/circuit 69 device 0. When the panel is reset from the Hot Keys on the front panel, it will send an event on zone/circuit 90, device 9.