Datasheet

PRODUCT INFORMATION
PRODUCT INFORMATION
Applications:
Features:
TGS 2611 - for the detection of Methane
* Domestic gas alarms
* Portable gas detectors
* Gas leak detector for gas appliances
* Low power consumption
* High sensitivity to methane
* Long life and low cost
* Uses simple electrical circuit
TGS2611-E00 Sensitivity Characteristics:
TGS2611-C00 Sensitivity Characteristics:
0.1
1
10
100
100 1000 10000 100000
Rs/Ro
Gas concentration (ppm)
Air
Ethanol
Hydrogen
Methane
Iso-butane
0.1
1
10
100
100 1000 10000 100000
Rs/Ro
Gas concentration (ppm)
Air
Ethanol
Hydrogen
Methane
Iso-butane
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY REC-
OMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES
ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT
BEEN SPECIFICALLY TESTED BY FIGARO.
The figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see
reverse side of this sheet). The Y-axis is indicated as sensor resistance ratio (Rs/Ro) which is defined as follows:
Rs = Sensor resistance in displayed gases at various concentrations
Ro = Sensor resistance in 5000ppm of methane
TGS2611 is a semiconductor type gas sensor which combines very high
sensitivity to methane gas with low power consumption and long life. Due to
miniaturization of its sensing chip, TGS2611 requires a heater current of only
56mA and the device is housed in a standard TO-5 package.
The TGS2611 is available in two different models which have different external
housings but identical sensitivity to methane gas. Both models are able to satisfy
the requirements of performance standards such as UL1484 and EN50194.
TGS2611-C00 possesses small size and quick gas response, making it suit-
able for gas leakage checkers.
TGS2611-E00 uses filter material in its housing which eliminates the influence
of interference gases such as alcohol, resulting in highly selective response to
methane gas. This feature makes the sensor ideal for residential gas leakage
detectors which require durability and resistance against interference gas.

Summary of content (2 pages)