Instructions / Assembly

10
Figure 16
Pairing Process:
The auto-learning process will only initiate
within the first 60 seconds of supplying power
to the fan.
Beginning with the fans power off, restore
power to the fan. Press and hold the “Fan
Off/Set” button for 6 seconds and release. If
the optional light kit is installed, the light will
blink twice. Once the receiver has detected the
frequency, the fan will automatically begin a
self-calibration process. The fan will begin to
operate and rotate in the counter-clockwise
direction on the highest RPM for 3 minutes.
When the counter-clockwise rotation has
finished, the fan will reverse and rotate in the
clockwise position on the highest RPM for 3
minutes. The fan will stop rotating once the
self-calibration process is complete. The total
self-calibration process will last approximately
6 minutes. During the self-calibration process
the remote control will not function and no
buttons should be pressed.
Pairing Process for Multiple Fans:
Select the desired frequency setting from the
back of the remote control. (Fig 16) You change
the frequency setting by arranging the small
switches numbered 1 through 4 in the up or
down position making 16 different frequencies
or combinations possible. Anytime you change
the frequency for a fan you must complete the
pairing process as described above.
Beginning with the power off to all fans, restore
power to the first fan. Select the desired frequency
setting. Complete the pairing process as described
above. Test the fan for proper operation.
Restore power to the second fan. Select the
desired frequency setting. Complete the pairing
process as described above. Test the fan for
proper operation.
Repeat this process until all fans have been
paired.
This receiver provides the following protective
function:
1. Lock Rotor Position: The DC motor has a
built-in safety against a stalled or locked rotor
condition (stalled blade rotation). If there is an
obstruction or fault with the motor, the current
monitoring function will automatically turn
power off to the motor after 30 seconds.
Remove the obstruction and turn the AC power
off. Restore power and re-start fan motor.
2. Over 80W protection: When the receiver
detects motor power consumption which is
greater than 80W, the receiver power will
be stopped and operation will immediately
discontinue. Wait for 5 seconds and then turn
the receiver power back on.
Frequency Switch
Code switch
ON
DIM
ON
DIM
ON ECE
1234
ON ECE
1234