Owners Installation, Operation, and Safety Manual Digital Liquid Meter Series 900D – High Flow Models 900DP, 900DP1.5, 900DPBSPT, 900DP1.5BPST 900DPX, 900D1.5DPX1.5, 900DPXBSPT, 900DPX1.5BSPT Tuthill Transfer Systems 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.
Table of Contents Owners Installation, Operation, and Safety Manual .............................................................. 1 Table of Contents .................................................................................................................. 2 Thank You! ............................................................................................................................ 2 About This Manual ........................................................................................
Safety Information WARNING! To insure safe and proper operation of your equipment, it is critical to read and adhere to all of the following safety warnings and precautions. Improper installation or use of this product can cause serious bodily injury or death! 1) 2) 3) 4) 5) 6) 7) NEVER smoke near the meter, or use the meter near open flames when metering a flammable liquid! Fire can result! A Fill-Rite Filter should be used on the meter outlet to insure no foreign material is transferred to the fuel tank.
IMPORTANT! If you have purchased this meter as part of a “Kit”, the meter flange base is drilled with 4 holes. This allows the meter to be used with 300 and 700 series pumps. Line the meter bracket up for installation and insert the bolts in the two holes that align with the corresponding holes on the pump outlet. Once the meter bracket is bolted securely in place install the two plugs in the holes that were not used to prevent moisture from entering them.
6. Pressing and holding the CAL button for 2 seconds before dispensing into a container will cause the meter to skip a fill operation and only change the unit of measure. IMPORTANT! For maximum accuracy, try to get as close as possible to the dispensed volume without changing flow rate. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The unit will default to a measured value based on the last calibration performed. The left-most digit will begin blinking.
IMPORTANT! When the meter is in the “Deep Sleep” mode, dispensing fluid will NOT turn the meter on. The meter will not display or accumulate any fluid that is dispensed while in “Deep Sleep” mode. • • • • • • • Pressing any button will turn the meter on when in deep sleep mode. (Fluid flow will not turn the unit on or cause it to exit deep sleep mode). The last count and selected totalizer is retained and displayed when the meter is turned on.
Storage If your meter is to be stored for a period of time, clean it thoroughly. This will help protect the meter from possible damage. Troubleshooting The following troubleshooting guide is designed to help you with basic diagnostics and repairs if you should encounter abnormal service from your 900 series digital meter. We recommend you use only genuine Fill-Rite parts. These parts, and additional service information is available through your authorized Fill-Rite dealer.
Accessing the Battery For access to the batteries (2 AA cell batteries) (figure 1): 1) 2) 3) Remove the four screws at the top and bottom of the front bezel (Torx #T25). Lift bezel off. Batteries are located Figure 1 on the back side of the display; use a Phillips head screwdriver to remove the cover screws to access the batteries. Reassemble by reversing this procedure. Meter Chamber Assembly The Meter Chamber consists of upper and lower chambers, a nutating disc, and four screws (figure 2).
Replacement Parts Information Replacement parts can be obtained through any authorized Fill-Rite dealer. Be sure to use only genuine Fill-Rite replacement parts for your service and maintenance needs. For a list of authorized dealers, please visit our web site at “www.fillrite.com”. Models FR901, 901N, 9011.
Repair Kits and Accessories Kit # Description 901DPMK300V 900 Series Meter (gallons) with Inlet Flange for FR300 & FR700 Pumps 901DPLMK300V 900 Series Meter (liters) with Inlet Flange for FR300 & FR700 Pumps Contents 900 Series Meter (gallons) Inlet Flange (4-hole) Required O-rings Required Fasteners 900 Series Meter (liters) Inlet Flange (4-hole) Required O-rings Required Fasteners 900 Series Digital Meters w / Pulser Certain 900 Series Digital Meters (model number suffix of DP) can be powered exter
Internal Power (Battery Power) All 900D Series Digital Meters are battery powered. The battery tray is located behind the faceplate on the circuit board (see illustration page 8). Power is supplied by two alkaline “AA” batteries. With normal use, these batteries should provide 2 – 4 years of use.
WARNING! Substitution of components may impair intrinsic safety! WARNING! To prevent ignition of combustible or flammable atmosphere, disconnect power before servicing. WARNING! To prevent ignition of flammable or combustible atmosphere, do not use a volt meter or similar powered tools during live maintenance.
Technical Specifications and Information Dimensions: 6.75” (H) x 8.46” (W) x 4.10” (D) Accuracy: ± 1.25 % Repeatability: ± 0.25% at calibrated flow rate. Flow Rate: 6 to 40 GPM Pressure Rating: 50 psi Construction: Aluminum Units of Measure: Ounces, pints, quarts, liters, gallons, 1 special “unit of measure” option. Counter: 4 digit resettable counter; (.01 – 9999 units). Totalizers: 7 digit non-resettable “Master” totalizer, 7- digit resettable secondary.
Tuthill Product Warranty Tuthill Transfer Systems (“Manufacturer”) warrants each consumer buyer of its Fill-Rite products (“Buyer”) from the date of invoice or sales receipt, that goods of its manufacture (“Goods”) shall be free from defects of materials and workmanship.
NOTES 16 DC001501-000