Instructions / Assembly
Figure 2
Valve #2
Valve #1
Valve #3
Plumbing Assembly of Bypass and Filtration System
5
CAUTION
Instructions below reference Figure 2.
1. Plan system location, support, layout and size.
2. Shut off main water supply. Depressurize water lines by opening a faucet downstream.
3. Using pipe cutters, remove a section of pipe in the install location corresponding to the size of the predetermined system assembly.
Keep a bucket and towel handy to catch and wipe up any water that drains from the line while cutting.
4. Assemble and install system as shown, observing correct ow direction of manifold. Use three shut-off valves and one ltration unit as shown.
Use copper pipe and sweated connections to assemble system. Support system by fastening bracket to wall or other framing. Alternatively, pipe
hangers may be installed on both sides of the filter head.
5. Insert lter into lter head. Push lter up, then turn one quarter of a turn to the right until it stops.
6. Ensure valve 1 and faucet downstream are open. Close valves 2 and 3. Turn on water supply, check for leaks.
7. While water is running through faucet, close valve 1, open valves 2 and 3. Allow lter to ll up.
8. Close valve 3, check for leaks again. If leaks, see Troubleshooting Section. If no leaks occur, open valve 3, let water run,
ushing air from the system for 10 gallons.
9. Close faucet.
10. Activate lter change indicator according to instructions on page 7.
To reduce the risk associated with property damage due to water leakage:
• On plastic ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic ttings, as damage may occur if overtightening occurs.
IMPORTANT INSTALLATION INSTRUCTIONS