UNO-DM-3.3/3.8/4.6/5.0TL-PLUS-US-Q Data sheet
FIMER_UNO-DM-3.3-3.8-4.6-5.0-TL-PLUS-US-Q__US_REV_C 15.06.2021
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. FIMER does not accept any
responsibility whatsoever for potential errors or possible
lack of information in this document.
For more information
please contact
your local FIMER
representative or visit:
fimer.com
We reserve all rights in this document and in the subject
matter and illustrations contained therein. Any
reproduction, disclosure to third parties or utilization of
its
contents – in whole or in parts – is forbidden
without
prior written consent of FIMER. Copyright© 2021 FIMER.
All rights reserved.
1)
The auxiliary output is used to supply the RSD contactors when required
2)
WLAN IEEE 802.11 b/g/n @2,4GHz
3)
When equipped with DC switch and wiring box
All data is subject to change without notice
Technical data and types
Type code UNO-DM-3.3-TL-PLUS-US-Q UNO-DM-3.8-TL-PLUS-US-Q UNO-DM-4.6-TL-PLUS-US-Q UNO-DM-5.0-TL-PLUS-US-Q
Environmental
Ambient air operating temperature range
-25...+60°C /-13...140°F
(derating above 50°C/122°F)
-25...+60°C /-13...140°F
(derating above 45°C/113°F)
Relative humidity 0-100% RH condensing
Acoustic noise emission level < 50 db (A) @1m
Maximum operating altitude without derating 6560ft (2000m)
Mechanical specifications
Enclosure rating Type 4X
Cooling Natural convection
Dimensions H x W x D 34 x 16.4 x 8.7 in (863 x 418 x 222 mm)
3)
Weight 35.3 lb (16 kg)
3)
Shipping weight 46lb (20,7kg)
3)
Mounting system Wall bracket
Conduit connections
Bottom: Markings for (2) Concentric KOs 1”, 3/4” and (2) KOs 1/2”
Sides: Markings for Concentric KOs 1”, 3/4”
3)
DC switch rating 600 V, 23 A @ 600 V, 38 A @ 500 V and 45 A @ 350 V
Safety
Isolation level Transformerless (floating array)
Safety and EMC standard UL1741, IEEE1547.1, CSA-C22.2 N. 107.1-01, UL1998 UL 1699B-2018, FCC Part 15 Class B
Grid standard UL 1741 SA, IEEE 1547, Rule 21, Rule 14 (HI)
Safety approval CTUVUS
Available models
Model with DC switch, wiring box, AFD, RSD supply
output (String level RSD)
UNO-DM-3.3-TL-PLUS-US-
SB-RA-Q
UNO-DM-3.8-TL-PLUS-US-
SB-RA-Q
UNO-DM-4.6-TL-PLUS-US-
SB-RA-Q
UNO-DM-5.0-TL-PLUS-US-SB-
RA-QU
Model with DC switch, wiring box, AFD, RSD PLC
transmitter (Module Level RSD)
UNO-DM-3.3-TL-PLUS-US-
SB-RA-Q-AP
UNO-DM-3.8-TL-PLUS-US-
SB-RA-Q -AP
UNO-DM-4.6-TL-PLUS-US-
SB-RA-Q-AP
UNO-DM-5.0-TL-PLUS-US-SB-
RA-QU -AP