Light dependent relays 12 - 16 A Garden and night lighting 11 NEON Shop displays Lighting for parks Streetlights and car park lighting SЕRIES
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
11 SERIES Light dependent relays 12 - 16 A Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.31 - 1 NO 16 A output contact • Sensitivity adjustment from 1 to 100 lux • One module, 17.5 mm wide • Low energy consumption • 24 V DC/AC supply version available 11.
11 SERIES Light dependent relays 12 - 16 A Relays for automatic control of lighting according to ambient light level - with separate light sensor 11.
11 SERIES Light dependent relays 12 - 16 A 11 SERIES Ordering information Example: 11 series light dependent relay with time switch, 1 CO (SPDT) 16 A contact, 230 V AC supply. 1 1 . 9 1 . 8 . 2 3 0 . 0 0 0 Series 0 Options 0000 = Standard Type 3 = 17.5 mm wide 4 = 35 mm wide 9 = 35 mm wide, with time switch Supply voltage 024 = 12…24 V (11.31 only) 230 = 230 V 230 = 110…230 V (11.31 only) 230 = (110…230)V AC/DC (11.91 only) No.
11 SERIES 11 SERIES Light dependent relays 12 - 16 A Wiring diagrams Type 11.31 Type 11.42 L/+ LL NN N/– A1 A2 21 24 011.02 14 Type 11.41 Type 11.91 L 11 12 B1 B2 L N N I Type 11.91 + 19.91 L II-2018,www.findernet.
11 SERIES Light dependent relays 12 - 16 A 11 SERIES Advantage of the “zero hysteresis” patented circuit: ensures reliable switching without wasting energy TYPE 11.41 “ZERO HYSTERESIS” LIGHT DEPENDENT RELAYS TRADITIONAL LIGHT DEPENDENT RELAYS OFF threshold ON/OFF threshold set threshold ON threshold Switch OFF level = Switch ON level. Patented “zero hyseresis” circuitry ensures reliable switching without wasting energy.
11 SERIES Light dependent relays 12 - 16 A 11 SERIES Functions 11.91 Switch-OFF time Switch-ON time NO NO YES NO YES YES Application examples Working as a standard light-dependent relay Working where lighting is not required from 10 PM onwards Working where lighting is not required between 1 AM and 5 AM Additional output - light dependent without time switch intervention AUX Y1 Y2 All the functions and the values can be set through the front joystick and are displayed on the front LCD.
11 SERIES Light dependent relays 12 - 16 A 11 SERIES Auxiliary output A solid state output at terminals Y1-Y2 is provided (rated 12 V DC, 80 mA/1 W max.): this can be used with the power module 19.91.9.012.4000 connected by the dedicated 011.19 connector. Or, it is possible to connect a suitable relay (for example, 38-48-49-4C-58-59 interface module) provided the coil is within the rating, and the wiring does not exceed 40 cm length.
11 SERIES 11 SERIES Light dependent relays 12 - 16 A Outline drawings 11.31 Screw terminal 11.42 Screw terminal 11.41 Screw terminal 11.91 Screw terminal 19.91 (power module for 11.91) Screw terminal 11.91 + 19.91 power module Screw terminal 11.91 19.91 10 II-2018,www.findernet.
SERIES Light dependent relays 12 - 16 A 11 SERIES Accessories 011.02 011.03 Light sensor (supplied with light dependent relay) 011.02 - Ambient temperature range: –40…+70 °C - Cadmium free - Non polarized - Double insulated with respect to light dependent relay supply - Not compatible with old 11.01 and 11.71 light dependent relay (to be used with 011.