Datasheet

I-2014, www.findernet.com
5
A
56
SERIES
56 SERIES
Miniature power relays 12A
Coil specifications
DC coil data, 2 pole relay
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
6 9.006 4.8 6.6 40 150
12 9.012 9.6 13.2 140 86
24 9.024 19.2 26.4 600 40
48 9.048 38.4 52.8 2400 20
60 9.060 48 66 4000 15
110 9.110 88 121 12500 8.8
125 9.125 100 138 17300 7.2
220 9.220 176 242 54000 4
AC coil data, 2 pole relay
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
* U
max
R I at U
N
(50Hz)
V V V
Ω
mA
6 8.006 4.8 6.6 12 200
12 8.012 9.6 13.2 50 97
24 8.024 19.2 26.4 190 53
48 8.048 38.4 52.8 770 25
60 8.060 48 66 1200 21
110 8.110 88 121 3940 12.5
120 8.120 96 132 4700 12
230 8.230 184 253 17000 6
240 8.240 192 264 19100 5.3
* U
min
= 0.85U
N
for normally open version.
DC coil data, 4 pole relay
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
6 9.006 5.1 6.6 32.5 185
12 9.012 10.2 13.2 123 97
24 9.024 20.4 26.4 490 49
48 9.048 40.8 52.8 1800 27
60 9.060 51 66 3000 20
110 9.110 93.5 121 10400 10.5
125 9.125 107 138 14200 8.8
220 9.220 187 242 44000 5
AC coil data, 4 pole relay
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
(50Hz)
V V V
Ω
mA
6 8.006 4.8 6.6 5.7 300
12 8.012 9.6 13.2 22 150
24 8.024 19.2 26.4 81 90
48 8.048 38.4 52.8 380 37
60 8.060 48 66 600 30
110 8.110 88 121 1900 16.5
120 8.120 96 132 2560 13.4
230 8.230 184 253 7700 9
240 8.240 192 264 10000 7.5
400 8.400 320 440 26000 4.9
R 56 - DC coil operating range v ambient temperature
2 pole relay
R 56 - AC coil operating range v ambient temperature
2 pole relay
1
2
normally open version
changeover version
1
2
2
R 56 - DC coil operating range v ambient temperature
4 pole relay
R 56 - AC coil operating range v ambient temperature
4 pole relay
1
2
changeover version
2
1
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.