Data Sheet

I-2018www.findernet.com
5
A
60
SERIES
60 SERIES
General purpose relays 6 - 10A
Flange mount - General purpose relay 10A
Type 60.62
- 2 pole, 10 A
Type 60.63
- 3 pole, 10 A
Faston 187, (4.8x0.8mm)
2 & 3 pole changeover contacts
AC coils & DC coils
Cadmium Free contacts
Contacts material options
For UL ratings see:
“General technical information” page V
60.62 60.63
2 pole, 10A power contacts
Flange mount
Faston 187
3 pole, 10A power contacts
Flange mount
Faston 187
For outline drawing see page 8
Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT)
Rated current/Maximum peak current A 10/20 10/20
Rated voltage/
Maximum switching voltage VAC 250/400 250/400
Rated load AC1 VA 2500 2500
Rated load AC15 (230VAC) VA 500 500
Single phase motor rating (230VAC) kW 0.37 0.37
Breaking capacity DC1: 30/110/220V A 10/0.4/0.15 10/0.4/0.15
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi
Coil specification
Nominal voltage (U
N
) VAC (50/60Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
VDC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220
Rated power AC/DC VA (50Hz)/W 2.2/1.3 2.2/1.3
Operating range AC (0.8…1.1)U
N
(0.8…1.1)U
N
DC (0.8…1.1)U
N
(0.8…1.1)U
N
Holding voltage AC/DC 0.8U
N
/0.5U
N
0.8U
N
/0.5U
N
Must drop-out voltage AC/DC 0.2U
N
/0.1U
N
0.2U
N
/0.1U
N
Technical data
Mechanical life AC/DC cycles 20·10
6
/50·10
6
20·10
6
/50·10
6
Electrical life at rated load AC1 cycles 200·10
3
200·10
3
Operate/release time ms 11/4 11/4
Insulation between coil
and contacts (1.2/50μs) kV 4 3.6
Dielectric strength
between open contacts VAC 1000 1000
Ambient temperature range °C –40…+70 –40…+70
Environmental protection RT I RT I
Approvals (according to type)
Z