Data Sheet
II-2016, www.findernet.com
12
SERIES
12 Series - Time switches 16 A
3
I
Digital time switch, weekly programming
- Can be programmed in “Classic” mode
via the joystick, or “Smart” mode via
smartphones with NFC communication
Type 12.61
- 1 CO 16A
Type 12.62
- 2 CO 16A
• Functions:
Switch ON, Switch OFF
Pulse: 1s…59min
• Minimum time interval setting - 1 minute
• Summer/Winter European, Australian, Brazilian time
• LCD status indication, set-up and programming
• Lock with a 4-digit PIN
• Back-light display
• Internal battery for set-up and programming
without supply, easily replaceable from the front
• Protective separation between supply and
contacts
• 35mm wide
• 35mm rail (EN60715) mount
• Cadmium free contact material
12.61 12.62
• Weekly programming
• 1 CO 16A
• Switch ON, Switch OFF, Pulse
• Weekly programming
• 2 CO 16A
• Switch ON, Switch OFF, Pulse
24 22 21
For outline drawing see page 12
Contact specification
Contact configuration 1 CO (SPDT) 2 CO (DPDT)
Rated current/Maximum peak current A 16/30 (120A - 5ms) 16/30 (120A - 5ms)
Rated voltage/Maximum switching voltage VAC 250/400 250/400
Rated load AC1 VA 4000 4000
Rated load AC15 (230VAC) VA 750 750
Nominal lamp rating:
230V incandescent/halogen W 2000 2000
fluorescent tubes with
electronic ballast W 1000 1000
fluorescent tubes with
electromechanical ballast W 750 750
CFL W 400 400
230V LED W 400 400
LV halogen or LED with
electronic ballast W 400 400
LV halogen or LED with
electromechanical ballast W 800 800
Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10)
Standard contact material AgSnO
2
AgSnO
2
Supply specification
Nominal voltage (U
N
) VAC (50/60Hz) 110…230 110…230
VDC 110…230 110…230
Rated power AC/DC VA (50Hz)/W 2.8/0.9 2.8/0.9
Operating range AC (50Hz) (0.8…1.1)U
N
(0.8…1.1)U
N
DC (0.8…1.1)U
N
(0.8…1.1)U
N
Technical data
Electrical life at rated load in AC1 cycles 100·10
3
100·10
3
Type of time switch Weekly Weekly
Memory locations for switching times 50 50
Minimum internal setting min 1 1
Accuracy s/day 1 1
Ambient temperature range °C
–20…+50 (see page 7,
diagram L12)
–20…+50 (see page 7,
diagram L12)
Protection category IP 20 IP 20
Approvals (according to type)