Datasheet

VI-2015, www.findernet.com
1
K
13
SERIES
13 SERIES
Electronic step relays 10 - 16A
13.81 - Electronic step relay - Rail mount - 1 Pole
13.91 - Electronic step relay and timing step relay
Switch box mount - 1 Pole
Fixed time (10minutes) timing function
selectable (13.91)
Use with 3 or 4 wire connection, with automatic
recognition by the relay
Control input can be continuously applied
Longer mechanical and electrical life, and much
quieter than electromechanical step relays
“Zero crossing load switching
Can be mounted behind blanking plates, as
widely used in residential wiring systems such
as; BTicino: Axolute, Matix, Living and Magic,
Gewiss: GW24, Vimar: Plana and Idea…(13.91)
35mm rail (EN60715) mount (13.81)
Cadmium free contact material
13.81/91
Screw terminals
13.81 13.91
1 NO (SPST-NO)
35mm rail (EN60715) mount
17.5mm wide
1 NO (SPST-NO)
Step relay and timing step
relay (10minutes)
For mounting within
residential switch boxes
For outline drawing see page 10
Contact specification
Contact configuration 1 NO (SPST-NO) 1 NO (SPST-NO)
Rated current/Maximum peak current A 16/30 (120 - 5ms) 16/20 (80 - 5ms)
Rated voltage/
Maximum switching voltage VAC 230/— 230/—
Rated load AC1 VA 3700 2300
Rated load AC15 (230VAC) VA 750 450
Nominal lamp rating:
230V incandescent/halogen W 3000 1000
fluorescent tubes with
electronic ballast W 1500 500
fluorescent tubes with
electromechanical ballast W 1000 350
CFL W 600 300
230V LED W 600 300
LV halogen or LED with
electronic ballast W 600 300
LV halogen or LED with
electromechanical ballast W 1500 500
Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10)
Standard contact material AgSnO
2
AgSnO
2
Supply specification
Nominal voltage (U
N
) VAC (50/60Hz) 230 230
VDC
Rated power VA (50Hz)/W 3/1.2 2/1
Operating range AC (50Hz) (0.8…1.1)U
N
(0.8…1.1)U
N
DC
Technical data
Electrical life at rated load in AC1 cycles 100·10
3
100·10
3
Maximum impulse duration continuous continuous
Dielectric strength between: open contacts VAC 1000 1000
supply - contacts VAC
Ambient temperature range °C –10…+60 –10…+50
Protection category IP 20 IP 20
Approvals (according to type)