Datasheet
VI-2015, www.findernet.com
5
K
13
SERIES
13 SERIES
Electronic step/monostable and call/reset
Functions
Type
13.01
Monostable
On closure of a switch between terminals (B2-B3) the output
contact will close, and remain so, until the switch opens.
Step relay (bistable)
After every impulse (B1-B2), the output contact changes state -
alternately switching from open to closed and vice versa.
13.11
13.12
(13.12 only)
Call and Reset relay
On momentary closure of the Set switch (S), the output contact
closes. Only a momentary closure of the Reset switch (R) will
open the output contact.
13.81
(RI) Step relay
After every impulse, the output contact changes state -
alternately switching from open to closed and vice versa.
13.91
(RI) Step relay
After every impulse, the output contact changes state -
alternately switching from open to closed and vice versa.
(IT) Timing step relay
On initial impulse the output contact closes and timing starts
for the pre-set duration (fixed 10min); On expiry of the time
delay, the output contact opens.
During the timing period it is possible to immediately open the
contact with a further impulse.
Operating mode setup for type 13.91
RI → IT
a) Remove the supply voltage
b) Press the control button
c) Apply the supply to the relay, keeping the button closed.
After 3 second, the light will flash twice to indicate the
selection of the “IT” function, or flash once for “RI” function.
IT → RI